Heart circulation diagnostics equipment
The work of the TempoHeart module is based on the method of scoring the heart rate vegetative regulation. This method is popular due to its high information value and non-invasiveness. Cannot be used
The MAX-ECG-MONITOR evaluation and development platform, featuring the MAX30003 clinical-grade AFE, analyzes data and accurately tracks heart signals (ECG and heart rate), as well as user status
HeartPlus AED is compact, portable device that analysis the hearts rhythm and delivers a defibrillation shock to re-establish the normal heart rhythm. HeartPlus NT-180 Guides the user through
records. Apply digital signal processor technology to achieve realtime fetal heart rate, auto- correlation operation to ensure that the detection of fetal...BFM series ultrasound fetal Monitor mainly applies to detect fetal heart rate in hospital, clinic etc. 5.6 inches TFT LCD displays 2 x US, 1x UC data...heart rate is accurate and reliable. 1.0 MHz pulse Doppler mode of operation, low ultrasonic dose, low noise, high sensitivity Ultrasound dose probe. Two...remote event marker - Pregnant women and medical staff can record at the same time. Including a variety of alarm functions: fetal heart rate over limit,
between two heartbeats, regardless of the heart rate or irregularities in the patients heartbeat. Bundling all process steps from development to series...(PMM) was developed and manufactured for the synchronization of CT imaging with the respiratory or heart rate of the patient. During data acquisition...with the CT scanner, the PMM has to record and analyse physiological data such as the ECG, pulse rate and a respiratory signal. A trigger signal...has to be derived from the ECG data in real time, triggering the CT scan in a defined heart phase. The PMM has to be integrated into the foot of the scanner...heart phase is identified based on the ECG data, the module sends a trigger signal to the CT scanner. This permits image capturing in the pause...With an intelligent controller from the customer, adaptive dosage modulation controlled by the ECG was realised, minimising the radiation exposure in the fast heart...saturation in the blood. It is used at a heart catheter measuring station. It can be used flexibly through its Bluetooth connection to the cardiac catheter...measuring station. During an examination using a catheter, it determines the local oxygen saturation in the patients heart ventricles without drawing...of the analysis unit was planned for different scenarios: As part of a haemodynamic measuring station in the heart catheter laboratory As part of a combined hybrid
model with (fetal heart rate) LCD digital display.It has audio output and can be connected with headphone&loudspeaker or recorder with audio...movement sounds of fetal heart rate at 12 week 2.6 Ultrasonic frequency:2.5MHZ 2.7 Battery:9V 2.8 Certificate:CE FDA approved 3. Main...specifications Product name: Angelsounds ultrasound fetal heart doppler Mode: JPD-100S5 Ultrasound frequency: 2.5MHz±3% Output power: <20mW Heart rate display...1. Description Jumper ultrasound fetal heart doppler JPD-100S5 is a lightweight portable fetal doppler, which can be used in hospital,...clinic and home for daily self-check by pregnant woman. This portable fetal heart detector contains components of ultrasonic signal transmitter
probe:solid,durable,anti-shocking and anti-falling down. III. Heart rate range:50-210BPM,resolution: ± bpm IV. Power: battery AAA*4 V: Size:236*242*77mm ...heart rate at the 16 weeks II. LCD display fetus heart rate III. record FHR and be transfmitted to another recording device through attached recording...Features: I. Poctable II. Lovely apperence and convenient to carry III. Built-in speaker to hear fetal heart beat IV. 3modes caculations...cable IV. Built-in speaker or through audio socket with headphone hear fetus heart beat Specifications: I. Urasound frequency: 3.3 MHz II. Ultrasonic
simulations. Systolic(mmHg) 20-250 Diastolic(mmHg) 10-200 Heart Rate,(bpm) 30-250 Pulse Volume,(cc) 0.1-2.4 Simulant characteristics The maximum pulse...volume:2.4cc The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc. Internal Adult cuff volume:20cc Internal neonate cuff volume:300cc Blood pressure...units: mmHg,kPa Heart Rate Accuracy:±1BPM Patient Conditions: Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM Mild exercise±1.5%±1BPM Strenuous...between target pressure and actual pressure:±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc Internal leak rate <2 mmHg per minute, with a minimum...and the real-time pressures.Leak rate displayed after 10 seconds. Pressure Relief Test Pressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak
a trigger signal to the CT scanner. This permits image capturing in the pause between two heartbeats, regardless of the heart rate or irregularities...imaging with the respiratory or heart rate of the patient. During data acquisition with the CT scanner, the PMM has to record and analyse physiological data...such as the ECG, pulse rate and a respiratory signal. A trigger signal has to be derived from the ECG data in real time, triggering the CT scan in a defined heart...in the patients heartbeat. Bundling all process steps from development to series production with one vendor and ongoing, transparent reporting to the customer led...was able to develop a sophisticated ECG analysis procedure. Once the corresponding heart phase is identified based on the ECG data, the module sends...was realised, minimising the radiation exposure in the fast heart movement phases. THE HAEMO BASE RESEARCH PROJECT The aim of the research project 'Haemo Base'...for different scenarios: As part of a haemodynamic measuring station in the heart catheter laboratory As part of a combined hybrid solution with a haemodynamic
heart timely and accurately. The device is applicable for ECG examination in medical and health institutions at all levels, providing accurate...2. Adopt real-time sampling, display and store mode, it has many functions, such as QRS wave analyzing in real-time, heart rate calculating...internal dispersion analysis, Heart Rate Variability (HRV) analysis, myocardium ischemia (STLE) analysis, Heart rate turbulence (HRT) analysis, Pacing ECG
efficient interference design, stable performance. 2.0MHz ultrasound probe; LCD displays FHR accurately, Syncheart rate flicker signal, battery symbol,...volume and fetal heartrate abnormal sound and light alarm, etc; Shut down automatically in one minute without input and have fetal heart rate...Application BF series ultrasound fetal doppler mainly applies to detect fetal heart rate in hospital, clinic and at home etc. Features Portable...over range alarm and battery power alarm; BF-500D + TFT can set the interface, count mode(four mode)alarm on/off & fetal heart rate range alarm settings,
abnormal of fetal heart rate. Specification: Ultrasound Frequency:2.5Mhz FHR Measurement Range:50~210 bpm Weight:155g Accuracy:±2bpm...Features: Listen to the fetal heart sounds by itself or cellphone. Monitor fetal heart rate and show fetal heart curve view by APP. You can share...fetal heart sounds by e-mail or other communicat ion networking with APP. Green light f lashes when capturing the fetal heart beat. Red light indicates
design provides a convenient use and carrying. Built-in speaker gives clear and loud voice. Large backlight LCD displays the fetal heart rate....sensibility can detect the pulse of 12th week fetus. Three calculation modes to calculate fetal heart rate: instant, 10 seconds average and manual. Packaging...Ultrasonic intensity: <20mW/cm2 Heart Rate Range: 50-210BPM Resolution: ± 1BPM Audio output power: 0.5W Auto Power-off: 1 minute with no signal
and carrying. Built-in speaker gives clear and loud voice. Large backlight LCD displays the fetal heart rate and Curve. Interchangeable waterproof probe. Full...of 12th week fetus. With fetal heart rate recording function. Functions: Ultrasonic probe: solid and durable, anti-shock, anti-falling...down Ultrasonic frequency: 2.5MHz ± 5% Ultrasonic intensity: <20mW/cm2 Heart Rate Range: 30-240BPM Resolution: ± 1BPM Charging limit: DC 5V power input Battery:
Obstetric detector can measure fetal heart rate, blood oxygen, blood pressure, convenience easy to operate, print results in real time. Fetal heart...rate, blood oxygen and blood pressure were measured completely at one-time. Clearly shows fetal heart rate, blood pressure, oxygen and other parameters.
Introduction Sonoline C2 Pocket Fetal Doppler is a hand-held fetal heart rate detecting device. It can be used in hospital and clinic for daily...software to display and print the heart rate trend graph, which can help the doctor diagnose and manage the case in time. Function Delicate...operation: view stored heart rate trend graph, cases management Automatic shutdown: The device will automatically turn off if there is no signal within 1...self-check by pregnant woman. The device uses color LCD of high resolution to display the fetal heartbeat waveform, integrated the function of time display...and menu control, FHR calculation, memory and review of FHR data, heartbeat waveform and heartbeat sound. It can communicate with PC, transfer the data to PC...values, bar graph and heartbeat waveform color display Alarming in red when the FHR value is out of the normal range. Memory and review function PC
indicates abnormal of fetal heart rate. 8.Low power consumption, continuously work for more than 8 hours with dry batteries 9.FHR Measurement Range: 50~210...bpm 10.Accuracy: ±2bpm 11.Detect fetal heart rate from 16th week of gestation 12.Data transmission and audio recording by wired connection 13.Option:...at the 16th week of gestation. ▪ Unique manufacturing technology is adopted to generate clear fetal heart sound by minimizing ultrasound noise. ▪ Ultrasonic...frequency: 3.0MHZ ▪ Battery: 9V 1.Integrated design for, easy to operate. 2.High sensitivity ultrasounzd probe: 3.0MHz 3.Built-in loud speaker 4.Low ultrasound...output with high quality 5.Listen to the fetal heart sounds by itself or cellphone. 6.Green light flashes when capturing the fetal heart beat. 7.Red light
when abnormal heart rate/respiratory rate/sleep routineor health risks occur. Sleep Routine & Report: Providing daily/weekly/monthly sleep routine analysis...Real-time Monitoring: Heart rates, respiratory rate, body movement, in/out of bed status, sleep rountine. Abnormal Alert: Send alert
Page 1 of 9
To use the full function of this web site, JavaScript needs to be enabled in your browser.
This is how you enable JavaScript in your browser settings: Read instruction