Surgival Co. S.A.U of Paterna (Valencia) at MEDICA 2021 in Düsseldorf -- MEDICA - World Forum for Medicine
Manage stand orders
Select Option

Surgival Co. S.A.U

Avda Leonardo Da Vinci 12-14 Parque Tecnológico, 46980 Paterna (Valencia)
Spain

Submit your contact details

Provide your contact details to the exhibitor. Optionally, you may also add a personal message.

Please log in

You must be logged in to send the contact request.

An error has occurred

Please check your internet connection or try again later.

Message has been sent

Your message to the exhibitor was sent successfully.

Hall map

MEDICA 2021 hall map (Hall 10): stand F65

Fairground map

MEDICA 2021 fairground map: Hall 10

Our range of products

Product categories

  • 01  Imaging and diagnostics / medical equipment and devices
  • 01.05  Implants and protheses
  • 01.05.03  Orthopaedic implants and prostheses

Our products

Product category: Orthopaedic implants and prostheses

GENUTECH CCK System

Genutech CCK revision knee prosthesis system
The Genutech® CCK revision knee system is a constrained system intended for patients with deficient prosthesis stabilization due to inadequate functioning of both the mediolateral and anteroposterior ligaments, as well as varus/valgus instability.
It is also indicated for major bone defects that may occur in combination with the existing instabilities.
It is always used with cement in femoral components and tibial trays. In straight and offset stems, use without cement is recommended initially.

Articular system characteristics:

Femoral component – tibial insert:

– Maximum congruence to minimize stresses and reduce friction and wear.

– The design of the condyles permits flexion up to 140º.

– Maximum mobility restriction through the design of the tibial post and the CCK intercondylar box. This restriction will affect the external-internal rotation and the varus-valgus motion.

– In a femorotibial joint replacement, there should always be congruency between the sizes of the femoral component and the insert.

– The system is designed to perform mechanically under the more demanding requirements of a revision knee arthroplasty.

Femoral component – patella:

– The design of the femoral component’s patellar canal permits a smooth and anatomical motion for the patella throughout the range of flexion.

– Maximum congruence to minimize stresses and reduce friction and wear.

Nonarticular system characteristics:

Tray – tibial insert:

– Total modularity among tray and tibial insert sizes.

– Triple fixation:

Anteroposterior clipping.
Anterior fixation bolt.
Metal reinforcement post that secures the insert on the tray, providing high stability and avoiding post breakage in the tibial insert.
– The system permits use of straight and offset stems to ensure greater stability in both the tibial and femoral zones. Augmentation blocks and supplements can also be added to cover any possible bone deficiency during the revision surgery. This will be applicable both for femoral components and CCK tibial trays.

– Its instrumentation was designed with two objectives: facilitating the surgeon’s work and minimizing patient risk.

More Less

Product category: Orthopaedic implants and prostheses

Karey Stem HA

The KAREY-HA® system for total hip arthroplasty has been designed to provide an optimal combination of strength and minimizing geometry setting offering a respectful anatomy in which it is integrated concept. Stem KAREY® -HA is intelligently designed:

a) At its proximal or metaphyseal area, has a progressive trapezoidal geometry allows optimum adaptation of the stem as well as a translational anti-, anti-rotational mounting prosthetic that provides a perfect primary stability avoiding collapse.

b) There is a progressive slots in the medial side to promote bone growth and join the anti-translational property (sinking) cited above.

c) In the distal zone has a hypo-sized favors progressive stiffness decreased stem avoiding this the “stress-shielding” mode

More Less

Product category: Orthopaedic implants and prostheses

Stem Karey cemented

The KAREY-C ® system for total hip arthroplasty has been designed to provide an optimal combination of strength and minimizing geometry setting offering a respectful anatomy in which it is integrated concept.

Stem KAREY-C ® is intelligently designed: at its proximal or metaphyseal area, has a progressive trapezoidal geometry allows optimum adaptation of the stem, as well as anti-translational attachment, anti-rotational delivers perfect primary stability prosthetic preventing its collapse.

More Less

About us

Company portrait

SURGIVAL (GRUPO COSÍAS) consists of two companies specialized in the production, marketing and distribution of implants for traumatology, prosthesis for orthopedic surgery and surgical instrumentation.

Its venture into the orthopaedic field began during the 80´s with a company known as ORBIMED whose main activity was distributing imported products of the best companies in the world at that time, a job that we still carry out today.

ORBIMED was the origin of our business projection and helped us to learn that the combination of product quality and service excellence would enable us to reach our goals and therefore the satisfaction of our customers. The trusting link that we have created with our customers has strengthened our position in the national market.