SMB CORPORATION OF INDIA of Mumbai, Maharashtra at MEDICA 2021 in Düsseldorf -- MEDICA - World Forum for Medicine
Manage stand orders
Select Option

SMB CORPORATION OF INDIA

13, 33-36, Prem Industrial Estate Subhash Road, Jogeshwari East, 400060 Mumbai, Maharashtra
India
Telephone +91 22 28345637, +91 98 20302218
Fax +91 22 28215157
girish@smbcorpn.com

Submit your contact details

Provide your contact details to the exhibitor. Optionally, you may also add a personal message.

Please log in

You must be logged in to send the contact request.

An error has occurred

Please check your internet connection or try again later.

Message has been sent

Your message to the exhibitor was sent successfully.

Media files

Hall map

MEDICA 2021 hall map (Hall 6): stand B64

Fairground map

MEDICA 2021 fairground map: Hall 6

Our range of products

Product categories

  • 01  Imaging and diagnostics / medical equipment and devices
  • 01.01  Diagnostics
  • 01.01.04  Colposcopes, equipment for gynaecological investigation and diagnosis

Our products

Product category: Disposable articles for hospitals

SMB HYPODERMIC SYRINGE

SMB Hypodermic syringe is device that is used to inject fluid into, or withdraw fluid from the body. A syringe consisting of a plunger that fits tightly within a cylindrical tube called a barrel. The plunger can be linearly pulled and pushed along the inside of the tube, allowing the syringe to take in and expel liquid through a discharge orifice at the front end of the tube.

The ETO Sterilized device is supplied in a peelable blister pack pouch.

The Hypodermic Syringe is a two-piece, single use, sterile or bulk non-sterile (BNS) hypodermic syringe with Luer Slip or male 6% (Luer Lock) conical lock connection, which are connectable to a compatible female 6% (Luer) connector. The syringe assemblies consist of a lubricated polypropylene barrel with a graduated scale and a polypropylene/HDPE plunger rod. The plunger rod is pulled back to aspirate fluids or depressed to inject or expel fluids. The barrel scale of the SMB Syringe incorporates a scale graduated in units of millilitres.

The syringe will supply with or without Needle.

This device is used for single use only.

Shelf life of the SMB Hypodermic syringe is up to 5 years.

Silent Features of Syringe
• Easy to draw up viscous allergenic extracts.
• Only 0.0021 ml dead space 98% less antigen waste.
• Smooth Plunger.
• Clear Barrel.
• Easy to read scale markings.
• Ultra sharp needle.

Advantages of Hypodermic Syringe
• The luer lock helps to ensure that the needle or tube attached will remain secure throughout the administration process of a treatment.

• Securing a proper connection between needle and patient, it ensures that there will be no issues when it comes to the venous lines or ports to the arteriolar lines.

• Luer lock of syringe avoids the chances of needle that could be lost in the patient.

• This technique avoids contamination as the port can be cleaned and fresh syringes can be used instead of injecting patients with a port that has been used multiple times with different patients.

• The luer lock ensures a tight fit between the connectors and the needles.

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Disposable articles for hospitals

SMB CORPORATION OF INDIA

Keeping the dream in mind to serve the mankind by providing high quality products with innovative technologies expertise ensuring safety of service provider and the end user Late Mr Ratilal Shah had established SMB Corporation of India in 1974.

 

Taking forward his father’s legacy to serve the mankind with same spirit Mr Girish R. Shah has joined the organization as its CEO in 1985 and Since then he has taken the SMB on new heights of Success.

 

Starting from the manufacturing of surgical sutures to Intrauterine Contraceptive devices and their accessories to the 2ml luer lock Hypodermic syringes SMB has achieved new milestones in the journey of success under the guidance of its CEO

 

Dedicating 4 decades in the manufacturing of high quality products in the sphere of healthcare SMB has its product acceptance in more than 140 countries around the globe.

 

It is a Star House exporter manufacturing indigenously versatile range of Medical devices Covering IUD and its insertion accessories and Disposable luer lock hypodermic syringes with needle in world class manufacturing facilities under Class 10000 clean room condition right from the process of moulding to assembling.

 

SMB facilities are certified with ISO 13485:2016 and ISO 14001:2015, Our Product range is CE marked and according to the latest directives of European Commission Medical devices Guidance document MEDDEC 2.1/3 Rev 3.

 

SMB IUD TCU 380A and TCU 380Ag, Thread retriever and Probe are approved by Health Canada, MDSAP, ANVISA, European Union SFDA and TFDA

 

SMB has the following Product range:

 

·         TCU380A

·         TCu 380Ag (Available in 3 Sizes :Mini, Normal & Maxi)

·         TCu 380Plus (Available in 3 Sizes :Mini, Normal & Maxi)

·         Cu 375 (Available in 2 Sizes :Standard and Sleek)

·         Cu 250 (Available in 2 Sizes : Standard and Sleek)

·         Post partum IUDs

·         Probe/Hysterometer (Single Sided, Double Sided and Polycarbonate probe)

·         IUD thread Retriever

·         IUD Insertion Kit( Pozzi tenaculam, cheron forceps, IUD thread cutting Scissors)

·         Tubal Rings

·         Cyto brush

·         Disposable Luer Lock 2 ml Hypodermic Syringes

 

 

 

 

Advantages of Copper IUDs:      

 

IUDs have numerous advantages over steroids, oral contraception and the levonogestral means of contraception

 

They have been undergone numerous clinical trials for studying their safe use, contraceptive effects and their continuation rates in different part of the world by Scientists and the renowned gynaecologists.

 

The Study on contraceptive effects of IUDs are published in numerous journals.

 

The following are some Advantages of IUDs which has been concluded by numerous studies are as follows:

 

IUDs has been proven-

 

·         Safe, Reversible Contraception

·         Easy to load

·         Longer intrauterine life

·         Hormone/Steroid free

·         Highly convenient

·         Immediately effective

·         can be used as emergency contraceptives

·         Daily attention not required

·         Safe contraceptive for breast feeding women

·         No touch technique for insertion

·         Can be used by women who cannot use Steroid Contraceptives

·         Safe for all women of child bearing age

·         Safe for use after abortion or miscarriage.

·         Women Regains fertility after removal of IUD

·         Longer continuation rate

·         Least menstrual disturbance

·         Gentle during insertion and removal process

·         TCU 380Ag mini has been proven the most useful IUD for nulliparous women

·         TCu 380A prevents pregnancy up to 10 years having 7 years of Shelf life

TCu 380Ag, TCu 380Plus & Cu 375 gives prevention from pregnancy upto 5 years having same Shelf Life of 5 years 

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB STERILE TCu 380A

Intrauterine Device - Long lasting Contraceptive for 10 years

 The above information is indicative only. The final decision of choosing correct model for patient lies under the responsibility of healthcare professional

Features:

Each SMB Sterile Copper T 380A T frame is made from compound of Low Density Polyethylene and Barium Sulphate (15% - 24%) wound with 176 mg of 0.25 mm diameter copper wire, and two copper sleeves on horizontal arm providing a surface area of 380 mm² ± 23 mm².

The 'T' is equipped with high-density polyethylene filament for easy removal.

It is packed together with an Insertion Tube and Solid Rod in a Continuous Polymer Film Pouch.

The Insertion Tube is equipped with a movable flange to aid in gauging the depth to which the Insertion Tube should be inserted through the  cervical canal and into the uterine cavity.

Centimeter Scale printed in blue is provided on the Insertion Tube for exact positioning of the flange on the Insertion Tube before Insertion.

It has a double copper winding system which have an advantage over the single winding system. This form rules out the possibility of protrusion and does not allow overlapping of wire.

The contraceptive effect is 99% and it does not affect Female hormonal system.

ADVANTAGES OF DOUBLE COPPER WINDING

Winding is difficult to unwind, Smooth and uniform winding over the stem, No protrusion or loose end near the stem hole, Uniform wire tension throughout the winding length makes it more elegant

The SMB TCu 380A IUD has under gone clinical studies in Vietnam for 60 months and was confirmed to be a safe and effective contraceptive.

It has also under gone clinical trials with :
 
a. LNG IUS and Oral Contraceptive in Turkey (Comparative study) - demonstrated higher protection against accidental pregnancy and lower complications level.

b. Injectable progestin in South Africa (Comparative study) - demonstrated TCu 380A more effective in preventing pregnancy than injectable progestin.

c. Effect on serum cancer antigen 125 level in Turkey (TCu 380A IUDs were seen to lower the antigen levels)

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB TCu 380AG

This IUD is available in three sizes viz. Mini, Normal & Maxi

The above information is indicative only. The final decision of choosing correct model for patient lies under the responsibility of healthcare professional

Features:

Each Y shaped SMB TCu 380 Ag frame is made from compound of Low Density Polyethylene and Barium Sulphate wound with 0.4 0mm diameter copper wire with silver core of 0.1mm providing a surface area of 380 mm2 ± 23 mm2.

The Y frame is equipped with Polyamide Monofilament thread (suture) for easy removal. It is packed together with an Insertion Tube and Rod in a Continuous Polymer Film Pouch.

The Insertion Tube is equipped with a movable flange to aid in gauging the depth to which the Insertion Tube should be inserted through the cervical canal and into the uterine cavity. Centimetre Scale printed in blue is provided on the Insertion Tube on customer request for exact positioning of the flange on the Insertion Tube before Insertion.

SMB TCu 380 Ag contains a Silver core in Copper wire making up approximately one third of the total diameter. It is 99% effective Intrauterine Contraceptive Device and does not affect Female hormonal system.

Advantages of Copper Silver IUDs:

·         The Silver Core delays the fragmentation of the wire and prolongs the life span of the device and reinforces the safety of the contraceptive effect.

·         The flexible arms offer a perfect fundal placement.

·         It is extremely gentle during insertion and removal process.

·         With Sutures now available in 2 colours - Blue and Green

·         It has a minimal side effects post insertion procedure

·         Longer contraceptive life with least menstrual disturbance

·         Mini model has been proven the most accurate model for Nulliparous women

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB TCu 380 Plus

Intrauterine Device - Long acting Contraceptive for 5 years
Available in three sizes viz. Mini, Normal & Maxi

The above information is indicative only. The final decision of choosing correct model for patient lies under the responsibility of healthcare professional

 

Features:

Each modified T shaped frame of SMB T Cu 380 Plus is made from compound of Low Density Polyethylene and Barium Sulphate (15% - 24%) wounded with 0.40 mm diameter copper wire providing a Copper surface area of 380 mm2 ± 23 mm2.

 

The T is equipped with polyamide monofilament thread (suture) for easy removal. It is packed together with an insertion tube and rod in a Continuous film peel able pouch.

 

The Insertion Tube is equipped with a movable flange to aid in gauging the depth to which the Insertion Tube should be inserted through the cervical canal and into the uterine cavity. Centimetre Scale printed in blue is provided on the Insertion Tube on customer request for exact positioning of the flange on the Insertion Tube before Insertion.

 

It is 99% effective Intrauterine Contraceptive Device and does not affect Female hormonal system. With Sutures now available in 2 colours - Blue and Green

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB Cu 375

Intrauterine Device - Long acting Contraceptive for 5 years
This IUD is available in two sizes viz. Standard & Sleek

The above information is indicative only. The final decision of choosing correct model for patient lies under the responsibility of healthcare professional

Each SMB Copper 375 (Cu 375) frame is made from compound of Low Density Polyethylene and Barium Sulphate (15% - 24%) with two flexible arms with spurs. 99.99% purity OFE Copper wire (Diameter 0.40 mm ± 0.01 mm) is wound around the stem, giving a total copper surface area of 375 mm2 ± 20 mm2.

The 'Frame' is equipped with Polyamide Monofilament (Suture) for checking the  Presence/position IUD and for easy removal.

 

It is packed with an insertion tube in a Continuous Polymer Film Pouch.

The Insertion Tube is equipped with a movable flange to aid in gauging the depth to which the Insertion Tube should be inserted through the cervical canal and into the uterine cavity. Centimetre Scale printed in blue is provided on the Insertion Tube on customer request for exact positioning of the flange on the Insertion Tube before Insertion.

The flexible side arms ensure that IUD remains in position as high as possible  against the fundus, without the uterine cavity being stretched.

SMB Cu 375 is 98-99% effective Intrauterine Contraceptive Device. It does not affect Female hormonal system.

SMB Cu 375 had been a  part of  study named “Copper IUD continuation, unwanted effects and cost consequences at 1 year in users aged under 30 – a secondary analysis of the EURAS-IUD study” THE EUROPEAN JOURNAL OF CONTRACEPTION & REPRODUCTIVE HEALTH CARE2021, VOL. 26, NO. 3, 175-183

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

5. SMB Post Delivery IUD TCu 380A

Intrauterine Device - Long lasting Contraceptive for 10 years
Features of the SMB Post Delivery IUD

The whole device comes in a sterile, easy to use, peelable pouch meant for single use only. Thus chances of infections are minimized. With its longer Loading Device (Consisting of Insertion tube and Stylet / Inserter Rod), the use of Insertion Forceps is avoided, thus no fear of cross contamination.

Ideal Time for Insertion of Postpartum IUD is Within 48 hours after delivery

Advantages:

·         This Postpartum Intrauterine Device is ideal for women who deliver at health care facilities and wish to either space or limit their subsequent pregnancies.

·         IUD is as effective as tubal ligation in providing contraceptive protection. Postpartum IUD is the best alternative to tubectomy for couples who wish to keep their options open for future family expansion.

·         Insertion after delivery avoids the discomfort related to interval insertion, some of the post-insertion side effects are masked by normal postpartum events (such as bleeding and cramps).

·         Women who receive PPIUCD show a high level of satisfaction with this choice of Contraception, and the rates of expulsion are low enough so that the benefits of Contraceptive protection outweigh the potential inconvenience of needing to return for care for that subset of women.


·         “Acceptance, perception, experience and satisfaction of the couple with postpartum intrauterine contraceptive devices (PPIUCD) Insertion is given in , Asian Pac. J. Health Sci. 2016:3(4):55-56, Aashika Janwadkar et al.”

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB IUD Accessories

Loading Devices:

 

Offering EASY, SAFE and QUICK NO TOUCH Technique

 

1. U-shape a Cup Shape Safeloads

 

These are specially designed for ease in loading of Copper T 380A. It is easy, Safe & a quick loading Device from SMB.

 

The design of SMB’s Loading device is registered in the Patent office with certificate No. 240937.

 

ADVANTAGES

 

·         The loading of IUD is accurate and requires minimum efforts.

·         Both the arms of T-frame are evenly loaded, allowing correct loading and insertion.

·         Offers no touch technique.

·         Easy for service provider.

 

2. SMB IUD Thread Retriever

 

Made up of medical grade Polypropylene a single use Sterile SMB IUD Thread Retriever is designed to retrieve the lost threads if they are within the endocervical canal or uterine cavity.

 

The Thread Retriever has been designed to simplify the process of retrieving IUD threads, and make the process more comfortable for both patient and practitioner.

 

The design of SMB's Thread Retriever is registered under the Design Registration No. 255883

 

ADVANTAGES

·         The Procedure is Simple, painless, atraumatic

·         Grooves on the upper side of the retriever helps to hitch the lost thread in the endocervical cavity

·         Textured handle gives the clinician greater control.

·         Generally no analgesia or local anaesthesia is required it can be carried out in a doctor's surgery or clinic setting.

·         This saves the patient time and inconvenience and may avoid the need for hysteroscopy

·         Sterile, single-use Thread Retriever eliminates the risk of cross contamination.

 



3. SMB Hysterometer/Probe

 

Ensuring ACCURACY...

 

For sounding the length of the uterine cavity SMB has developed the Sound/Hysterometer or Probe in three different variants for the ease of medical practitioners

 

The three Variants of Probe are as follow:

 

·         SMB Single Sided Probe with Cursor

·         SMB Double Sided Probe with Cursor

·         SMB Angled Probe with Cursor

 

 

Variant 1: SMB Single Sided Probe with Cursor

 

A graduated sounding instrument for measuring the depth of the uterine cavity. It is a Gamma sterilized readily usable device. The design of SMB’s Hysterometer is registered under the Design Registration No. 240938.

 

It is an instrument made from medical grade ABS plastic, used for probing and dilating the uterus as well as measuring the length of the cervical canal.

 

Features:

 

·         Total Length: 255 mm

·         Calibrated Number Scale up to: 12cm from the tip on both the side

·         Scale length: 12 cm from the tip

 

ADVANTAGES

 

·         It is for single use only.

·         It is straight, slightly conical and centimetre marked with adjustable positioned

             to be set on the external orifice of the cervix.

·         The rounded tip allows a comfortable insertion through the cervical canal.

·         The handle is a short, smooth thumb grip has grooves for improved grip.

·         It also has graduated centimeter markings.

·         Measurement scale ranges from 6 to 12 cm (1cm resolution) and allows a direct reading on the Probe / Hysterometer.


Variant 2: SMB Double Sided Probe with Cursor

 

It is a malleable instrument made from medical grade polypropylene, used for probing and dilating the uterus as well as measuring the length of the cervical canal.

The design of SMB’s Hysterometer is registered under the Design Registration No. 278101.

 

Features:

 

·         Total Length: 270 mm

·         Calibrated Number Scale length up to: 10cm from the tip on both the sides.

·         This is a '2-in-1' device (Both CH12 and Ch14 sizes of the probes present)

·         Approved by Health Canada under Licence number 96894

·         Approved by ANVISA under Cadastro Registration no. 80117580723

 

 

ADVANTAGES

 

·         Strong but flexible

·         Only for single-use

·         Double-ended combined device designed for gentle dilation of the cervix assess the depth of the uterus.

·         The smooth and rounded ends are specially designed to allow gradual dilation of the cervix, whilst reducing risk of perforation.

 

Variant 3: SMB Angled Probe with Cursor

 

It is a malleable instrument made from medical grade polypropylene, used for probing and dilating the uterus as well as measuring the length of the cervical canal.

The design of SMB's Hysterometer is registered under the Design registration no.278102.

 

Features:

·         Total Length: 265 mm

·         Calibrated Number Scale up to: 18 cm from the tip

·         Scale length: 18 cm from the tip

·         Approved by Health Canada under license no. 96894

·         Approved by ANVISA under Cadastro Registration no. 80117580723

 

 

Advantages:

·         This Probe has curve on the tip.

·         The handle is long, smooth and improved thumb grip.

·         It also has graduated centimetre markings.

·         With Visibly Enhanced Marking

 

 

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB IUD Kit

Ensuring EASE and PERFECTION...

For mitigating the cross contamination caused by using resterilized products SMB has developed the single use, Sterile IUD Insertion Kit having components namely IUD Thread Cutting Scissors, Pozzi tenaculams and Cheron forceps

a) SMB Cheron Forcep

 
Product code: CRF

Design Registration No. 288755

Approved by ANVISA under Cadastro Registration no. 80117580724

The device is mainly used for the holding of cotton wool dipped into the antiseptic Solution while cleansing the cervix and vaginal wall to wipe all secretion away from the external OS
 

b) SMB Pozzi Tenaculum

 

Product Code: PZT

Design Registration No. 288754

 

The Ultimate use of Pozzi Tenaculums is to grasp the anterior lip of the cervix while inserting the IUD so that steady downward traction to straighten the uterine axis can be maintained without cervical laceration

 

 

c) SMB IUD Thread Cutting Scissor

 

Product code: TCS

Design Registration No. 288753

 

SMB IUD Thread cutting scissors are used for cutting the extra length of the monofilament of IUD which protrudes out after insertion of IUD.

More Less

Product category: Colposcopes, equipment for gynaecological investigation and diagnosis, Universal medical commodities, Disposable articles for hospitals, Incontinence systems and stoma aids

SMB TUBAL RINGS

Features:

 

Each Tubal Rings is  a cut Tube of 2.5 mm width made up of Silastic® RX 50R Medical Grade Radio opaque special Tubing which conforms to Indian Standard IS 13009 : 2000

 

The purpose of the SMB Tubal Ring applied by laparoscopy is to obstruct the Fallopian tube to achieve female sterilization. The product conforms to IS 13009: 2000

 

Packaging: sterilized by Gamma radiation a pair of Tubal rings is packed in Tyvek pouch

 

Shelf Life: 4 Years from date of Manufacturing/Sterilization

 

 

Advantages of Tubal Ligation

 

·         Tubal ligation is a permanent method of birth control offering immediate and highly effective protection against unexpected pregnancy

·         This mean of birth control has very few side effects

·         It is cost-effective in long term and requires no daily attention

·         Effectively protects women whose lives would be in danger if they were to conceive

·          No recurring contraception costs

·         Does not affect breast feeding

·         Simple surgery usually done under local anaesthesia

·          No long-term side effects

·          No change in sexual function (no effect on hormone production by ovaries) |

·         Decreased risk of ovarian cancer

·         Minimal operating time and patient is relieved the same day

·         Minimal surgical intervention | Potential reversibility (success rate is up to 90%)

More Less