Molbio Diagnostics (P) Limited of Verna, Goa at MEDICA 2020 in Düsseldorf -- MEDICA - World Forum for Medicine
Manage stand orders
Select Option

Molbio Diagnostics (P) Limited

L 46, Phase IID, Verna Industrial Estate, 403722 Verna, Goa
India

Submit your contact details

Provide your contact details to the exhibitor. Optionally, you may also add a personal message.

Please log in

You must be logged in to send the contact request.

An error has occurred

Please check your internet connection or try again later.

Message has been sent

Your message to the exhibitor was sent successfully.

Contact

Sriram Natarajan

Director and Chief Executive Officer of Molbio Diagnostics Pvt. Ltd.

Phone
+91 9890306689

Email
nsriram@molbiodiagnostics.com

Chandrasekhar Nair

Director and Chief Technical Officer of Molbio Diagnostics Private Limited

Phone
+ 91 9448377317

Email
chandynair@molbiodiagnostics.com

Sumit Mitra

President, Global Sales & Marketing

Phone
+919822384883

Email
sumitmitra@molbiodiagnostics.com

Shiva Sriram

National Sales Manager

Phone
+91 9823196689

Email
shiva.sriram@molbiodiagnostics.com

Shivraj Bhoite

Manager-Technical Services

Phone
+91 8446449570

Email
shivrajmolbio@molbiodiagnostics.com

Ana Claudia

Head of Latin America & Caribbean Region

Phone
+55 11 98433-4867

Email
ana.campana@molbiodiagnostics.com

B Mani Subramani

Business Consultant -Europe

Phone
+44 7482513595

Email
bmanisubramani@molbiodiagnostics.com

Our products

Product category: Polymerase chain reaction (PCR)

Truelab™ Uno Dx Real Time Quantitative micro PCR Analyzer

Fully automatic Real time Quantitative micro PCR analyzer, three wavelength system, performs 10-12 tests in 8 hours
Key Features
- Battery Operated
- Portable
- Runs On Any Truenat Chip
- Completely Randomized Operation
- Performs 10-12 Tests In 8 Hours
- Three Wavelength System
- Fully Automatic

More Less

Product category: Polymerase chain reaction (PCR)

Trueprep® AUTO v2 Universal Cartridge Based Sample Prep Device

Key Features
- Fully Automatic
- Cartridge Based
- Works With Multiple Sample Types
- DNA/RNA Extraction in ~20 Minutes
- Proprietary Matrix Based Extraction
- High Purity and Efficiency
- Point-of-Care
- Portable
- Battery Operated

More Less

Product category: Polymerase chain reaction (PCR)

Truelab™ Duo Real Time Quantitative micro PCR Analyzer

Fully automatic Real time Quantitative micro PCR analyzer, two channel-three wavelength system, performs 20-24 tests in 8 hours
Key Features
- Fully Automatic
- Three Wavelength System
- Performs 20-24 Tests in 8 Hours
- Completely Randomized Operation
- Runs on any Truenat Chip
- Portable
- Battery Operated

More Less

Product category: Polymerase chain reaction (PCR)

Truelab™ Quattro Real Time Quantitative micro PCR Analyzer

Fully automatic Real time Quantitative micro PCR analyzer, Four channel-three wavelength system, performs 40-48 tests in 8 hours
Key Features
- Fully Automatic
- Three Wavelength System
- Performs 40-48 Tests in 8 Hours
- Completely Randomized Operation
- Runs on any Truenat Chip
- Portable
- Battery Operated

More Less

Product category: Polymerase chain reaction (PCR)

Trueprep® AUTO v2 Universal Cartridge Based Sample Prep Kit

Intended Use
Trueprep AUTO v2 Universal Cartridge Based Sample Prep Kit works with Trueprep AUTO v2 Universal Cartridge Based Sample Prep Device and is used for extraction and purification of nucleic acids from a wide range of biological specimens
Key Features
-Cartridge based
-Composite and complete reagent pack
-Cartridge with pre-loaded Internal Positive Control (IPC) that validating the analysis from sample to result Cartridge based
-Composite and complete reagent pack

· Cartridge with pre-loaded Internal Positive Control (IPC) that validating the analysis from sample to result

More Less

Product category: Polymerase chain reaction (PCR)

Trueprep® AUTO MTB Sample Pre-treatment Pack

Intended Use
It is used to liquefy and pretreat the pulmonary and EPTB specimen before proceeding for extraction and purification of nucleic acids using Trueprep AUTO Universal Cartridge Based Sample Prep Kit and Trueprep AUTO Universal Cartridge Based Sample Prep Device.
Key Features
- Composite and complete reagent pack
- Compact kit size

More Less

Product category: Polymerase chain reaction (PCR)

Trueprep® AUTO Universal Sample Pre-treatment Pack

Intended Use
It is used to pre-treat the samples such as whole blood/ serum/ plasma/ urine/stool/swab specimen before proceeding for extraction and purification of nucleic acids using Trueprep AUTO Universal Cartridge Based Sample Prep Kit and Trueprep AUTO Universal Cartridge Based Sample Prep Device. Sample Pre-treatment decontaminates the specimen and makes it ready for storage/ transportation/ extraction.
Key Features
- Composite and complete reagent pack
- Compact kit size

More Less

Product category: Polymerase chain reaction (PCR)

Trueprep® AUTO Transport Medium for Swab Specimen Pack

Intended Use
It is intended for use with clinician-collected endocervical, vaginal, anorectal, nasal and throat swab specimens. The transport media is used as a medium for collection, decontamination and transport of various types of swabs specimens before proceeding for pre-treatment using Lysis buffer, extraction and purification of nucleic acids using Trueprep Universal Cartridge Based Sample Prep Kit and Trueprep Universal Cartridge Based Sample Prep Device. The transport medium will keep the nucleic acids of the respective organism intact thus maintaining the integrity of the nucleic acids. The medium does not maintain the viability of the microorganism. The collection and transport medium ensures for the safe collection and transport of the microorganisms which includes bacteria and viruses from the site of collection to the testing centre.
Key Features
- Composite and complete reagent pack
- Compact kit size

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ COVID-19

Intended Use
Semi quantitative detection of SARS CoV-2 RNA in human oropharyngeal and nasopharyngeal swab specimen and aids in detection and confirmation of SARS CoV-2 infection and diagnosis of COVID-19. The test detects the E and Orf1a genes of the virus
Key Features
- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with pre-set data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

Similar Products:
Truenat™ Beta CoV :
http://www.molbiodiagnostics.com/product_details.php?id=54
Truenat™ SARS CoV-2: http://www.molbiodiagnostics.com/product_details.php?id=55

Video Link: https://www.youtube.com/watch?v=5kJUw7gJlAQ


More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ MTB

"WHO Endorsed Tests"

Intended Use

Quantitative detection and diagnosis of Mycobacterium tuberculosis (MTB) in human pulmonary and EPTB specimens and aids in the diagnosis of infection with MTB

Key Features

- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with pre-set data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

Similar Products:
Truenat™ MTB Plus : http://www.molbiodiagnostics.com/product_details.php?id=49
Truenat™ MTB-RIF Dx  : http://www.molbiodiagnostics.com/product_details.php?id=25

Products Coming Soon:
Truenat™ MTB INH (
Chip-based Real Time PCR test for Isoniazid resistant Mycobacterium tuberculosis)
Truenat™ MTB FQ (
Chip-based Real Time PCR test for Fluroquinolone resistant Mycobacterium tuberculosis)
Truenat™ MTB BDQ (
Chip based Real Time PCR Test for Bedaquiline Resistance Mycobacterium tuberculosis)  

Video Link:
https://www.youtube.com/watch?v=ydR2I5S2v3c&t=91s

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HBV

Intended Use
Quantitative estimation of the Hepatitis B Virus (HBV) in human blood/serum/plasma specimen and aids in the diagnosis of infection with Hepatitis B virus and in the estimation of viral load
Key Features

- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with pre-set data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HCV

Intended Use
Quantitative detection and the diagnosis of Hepatitis C virus (HCV) in whole blood/plasma/serum and aids in the monitoring of HCV viral load of patients with HCV infection
Key Features
- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with pre-set data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ H1N1

Intended Use
Semiquantitative detection of H1N1 virus in human throat and nasal swab specimen and aids in the diagnosis of infection with H1N1
Key Features
- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with pre-set data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ Influenza A/B

Intended Use
Semiquantitative detection of Influenza A and Influenza B virus in human throat and nasal swab specimens and aids in differential diagnosis of infection with Influenza A and/or Influenza B virus
Key Features
- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with lot specific data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ CT/NG

Intended Use
Semiquantitative detection of Chlamydia trachomatis and Neisseria gonorrhoeae in female endocervical and vaginal swab specimens, male urethral swab specimen and male and female urine specimen and aids in the diagnosis of symptomatic or asymptomatic infection with Chlamydia trachomatis and/or Neisseria gonorrhoeae
Key Features
- Assay based on Taqman chemistry
- High primer sensitivity and specificity
- Micro chip based real-time PCR assay
- Minimal sample requirement @ 6µL
- Smart chip with lot specific data for quantitation of results
- Chip re-use lock
- Reaction port with contamination/evaporation resistant design

Similar Products:
Truenat™ CT : http://www.molbiodiagnostics.com/product_details.php?id=18
Truenat™ NG : http://www.molbiodiagnostics.com/product_details.php?id=19

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ GBS

Intended Use
Semiquantitative detection and diagnosis of group B streptococcus in vagino-rectal swabs, cerebrospinal fluid (CSF) and Blood/Serum/Plasma specimen and aids in the diagnosis of infection with group B streptococcus
Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HPV-HR

Intended Use
Semiquantitative detection of high risk Human Papillomavirus (HPV) types 16, 18, 31 and 45 in female cervical specimens collected by a clinician. It aids in the differential diagnosis of symptomatic or asymptomatic infection with high risk HPV types 16, 31 and 18, 45
Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ Trich

Intended Use
Semiquantitative detection of Trichomonas vaginalis in female endocervical and vaginal swab specimens, male urethral swab specimen and male and female urine specimen and aids in the diagnosis of symptomatic or asymptomatic infection with Trichomonas vaginalis
Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HIV-1

Intended Use
Quantitative detection and diagnosis of human immunodeficiency virus type 1 (HIV-1) in whole blood/plasma and aids in the monitoring of the HIV-1 viral load of patients with HIV-1 infection

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ Dengue/Chikungunya

Intended Use
Quantitative detection of Dengue and Chikungunya virus in human blood/serum/plasma specimen and aids in the differential diagnosis of infection with Dengue and/or Chikungunya virus

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

Similar Products:
Truenat™ Dengue : http://www.molbiodiagnostics.com/product_details.php?id=9
Truenat™ Chikungunya : http://www.molbiodiagnostics.com/product_details.php?id=10

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HLA-B27

Intended Use
Qualitative detection of HLA-B27 in human blood specimen and aids in the diagnosis of HLA-B27 typing

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ Malaria Pv/Pf

Intended Use
Quantitative detection Plasmodium vivax and Plasmodium falciparum in human blood specimen and aids in the diagnosis of infection with Malaria caused by Plasmodium vivax and/or Plasmodium falciparum

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

Similar Product
Truenat™ Malaria Pf :  http://www.molbiodiagnostics.com/product_details.php?id=48

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ Salmonella

Intended Use
Qualitative detection and diagnosis of Salmonella in human blood and aids in the diagnosis of infection with Salmonella

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ Rabies

Intended Use
Semiquantitative detection of Rabies Virus in Cerebrospinal fluid (CSF), saliva, brain tissue, corneal swabs specimens of animals and aids in the diagnosis of Rabies virus

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HAV

Intended Use
Quantitative detection and diagnosis of Hepatitis A virus in human blood /serum/ plasma specimen and aids in the diagnosis of infection with Hepatitis A Virus. This test is also intended for qualitative detection and diagnosis of Hepatitis A Virus in Stool sample

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

 

More Less

Product category: Polymerase chain reaction (PCR)

Truenat™ HEV

Intended Use
Quantitative detection and diagnosis of Hepatitis E virus in human blood /serum/ plasma specimen and aids in the diagnosis of infection with Hepatitis E Virus. This test is also intended for qualitative detection and diagnosis of Hepatitis E Virus in Stool sample

Key Features
- Reaction port with contamination/evaporation resistant design
- Chip re-use lock
- Smart chip with lot specific data for quantitation of results
- Minimal sample requirement @ 6µL
- Micro chip based real-time PCR assay
- High primer sensitivity and specificity
- Assay based on Taqman chemistry

More Less

Company news

Date

Topic

Download

Nov 13, 2020

Innovative point-of-care molecular diagnostic test for COVID-19 in India

A similar approach was used in India to augment testing for COVID-19 in underserved areas and health-care facilities. A combination of different tests and testing platforms has been used to augment capacity to 1·2 million tests per day, as of Sept 25, 2020.2 Indigenous portable Truelab (Molbio Diagnostics, India) workstations, previously used and recommended by WHO for tuberculosis3 and also deployed for detection of Nipah virus disease (unpublished) and leptospirosis (unpublished), are now being used for detection of SARS-CoV-2.

More Less

Jul 2, 2020

WORLD HEALTH ORGANIZATION ENDORSES TRUENAT TESTS FOR INITIAL DIAGNOSIS OF TUBERCULOSIS AND DETECTION OF RIFAMPICIN RESISTANCE

  • World Health Organization (WHO) endorses rapid molecular Truenat™ assays as initial tests to identify tuberculosis and detect rifampicin resistance in updated policy guidelines
  • Truenat molecular diagnostic tests for TB are now approved by WHO; these are suited for use at the point-of-care in low-resource primary healthcare settings
  • Data from FIND-coordinated multicentre field evaluations indicate high diagnostic accuracy of Truenat in intended settings of use

More Less

Jun 19, 2020

Explained: How TrueNat test works

A few weeks ago, the Indian Council of Medical Research (ICMR) approved the use of TrueNat machines, manufactured by a Goa-based company, for carrying out confirmatory tests for Covid-19 disease.

More Less

Jun 13, 2020

Centre deploys tuberculosis testing platform TrueNAT to ramp up COVID-19 tests

With COVID-19 cases rising at a faster pace, the Centre has fallen back upon its extensive tuberculosis testing facilities to ramp up testing for SARS CoV-2 virus. The TrueNat machines have been extensively used across almost every district for cond...

More Less

About us

Company details

For long Molecular Diagnostics has been the domain of large central laboratories requiring patients and samples to travel long distances for a test to be conducted. These pose several logistic and technical challenges leading to increased costs and delayed results. The veracity of such results and impact of such intervention in treatment outcome have always been questionable. This has led to a poor uptake of such reliable and cutting edge technologies that have potential to save millions of lives, mitigate sufferings and reduce disease burden and anti-microbial resistance. The lack of timely access to good diagnostics has been the bane of health care needs, particularly of the Low and Middle Income Countries.

The Truelab Real Time quantitative micro PCR system from Molbio Diagnostics brings PCR technology right to the point-of-care, at all laboratory and non-laboratory settings, primary centres, in the field, near patient, essentially at all levels of healthcare thereby decentralizing and democratising access to molecular diagnostics. With a large and growing menu of assays for infectious diseases, this rapid, portable technology enables early and accurate diagnosis and initiation of correct treatment right at the first point of contact. The platform is infrastructure independent and provides complete end to end solution for disease diagnosis. With proven ability to work even at Primary Health Centres and with wireless data transfer capability, this game changing technology brings in a paradigm shift to the global fight in control and management of devastating infectious diseases.

The system works on disease specific Truenat microchips for conducting a real time PCR. The sample preparation (extraction and purification) is done on a fully automated, cartridge based Trueprep AUTO sample prep device.

We from Molbio are proud to bring in this revolutionary technology and commit ourselves to continuous efforts towards improving the health and well being of the global population.

Key Impact of Truenat
Molecular Diagnostics is the state of the art in Diagnosis of infectious diseases. It works on the principle of DNA amplification, hence provides the ability to diagnose disease early in infection because of its excellent sensitivity and specificity. This technique has thus far, been limited to centralized laboratories due to dependency on complex and expensive infrastructure, highly skilled manpower, special storage conditions and need for batch testing. This results in high turn round time and poses major logistics challenges such as sample degradation, contamination, delays, etc.

Molbio now offers a 'global first' platform that can perform Molecular Diagnostics for infectious diseases at the point-of-care - Truelab Real Time Quantitative micro PCR System. This compact battery-operated system has single testing capability and provides sample to result within 1 hour. Hence, it enables same day reporting and initiation of evidence-based treatment for the patient. It also has real-time data transfer capability (through SMS/E-mail/data push) for immediate reporting of results in emergency cases.

Doctors and patients benefit from this technology by having a definitive diagnosis, early in the infection cycle, at the point of first contact so appropriate treatment can be initiated. Early and timely intervention also helps in preventing spread of the disease.

ICMR, after extensive validations has found Truenat to be a more sensitive and specific test and hence recommended it as a replacement to smear microscopy for diagnosis of TB and Rifampicin resistance under the RNTCP algorithm. Ministry of Health has now initiated roll-out of the test across India, with Andhra Pradesh being the first state to use Truenat as a frontline tool for TB detection at Primary Health Centre level. With this intervention, the state is seeing a substantial increase in case detection.

More Less

Company data

Number of employees

100-499

Foundation

2000

Area of business

Diagnostics

Company information as a PDF file