Taidoc Technology Corporation of New Taipei City at MEDICA 2018 in Düsseldorf -- MEDICA - World Forum for Medicine
Manufacturers OEM

Taidoc Technology Corporation

6F., No. 127, Wugong 2nd Road, Wugu District, 24888 New Taipei City
Taiwan
Telephone +886 2 6625 8188
Fax +886 2 6625 0288
sales@taidoc.com

Hall map

MEDICA 2018 hall map (Hall 3A): stand 3AD11

Fairground map

MEDICA 2018 fairground map: Hall 3A

Contact

Kenny Chi

Phone
+886930947289

Email
kenny_chi@taidoc.com.tw

Steven Lin

Phone
+886935169268

Email
steven.lin@taidoc.com.tw

Our range of products

Product categories

  • 01  Electromedical Equipment / Medical Technology
  • 01.01  Diagnostics
  • 01.01.08  Devices for measuring body temperature / thermometer
  • 01  Electromedical Equipment / Medical Technology
  • 01.06  Intense medicine / anesthesiology / respiration
  • 01.06.04  Inhaler and aerosol appliances
  • 03  Diagnostics
  • 03.02  Immunochemistry testing, immunology testing
  • 03.02.01  Immuno assay testing

Our products

Product category: Analyser systems / equipment, Other equipment for clinical chemistry, Immuno assay testing

TD-4611 Point of Care Glycated Hemoglobin (HbA1c) Analyzer

Feature 
No pretreatment; no pipetting required
Tiny sample volume (≤0.2ul) 
• Painless blood collection procedure

All-in-one analyzer 
• Embedded thermal printer

Simple operation!
• Graphical user interface
• Fully automatic operation
• 3-step operation

Certified by:
• IFCC
• NGSP

ANALYZER SPECIFICATION
  • Model No.: TD-4611
  • Measuring method: Photometry
  • Sample Type: Whole blood - Fingertips capillary or EDTA venous blood
  • Sample Size: ≦ 0.2 μl
  • Reaction Time: ≦ 6 mins
  • Measuring Range: 4 % ~ 16 %
  • Precision: CV <5%
  • Display unit: Percentage (%) or mmol/mol
  • Memory Capacity: 10,000 results
  • Patient ID/Operator ID Entry: Barcode reader or Keyboard (Optional)
  • Dimensions: 13.4 (H) x 19.2 (W) x 23.5 (D) cm
    5.28 (H) x 7.67 (W) x 9.25 (D) inch
  • Weight: 3.8 kg (8.38 Ibs)
  • Operating Condition: 15-32 ºC (59-89.6 ºF), 10-90 % R.H.
  • Storage Condition: 10-35 ºC (50-95 ºF), 10-90 % R.H.
CARTRIDGE SPECIFICATION
  • Model No.: TD-4601
  • Measuring method: Immunoassay
  • Dimensions: 73.3 (L) x 58.2 (W) x 12.6 (H) mm
    2.89 (L) x 2.20 (W) x 0.5 (H) inch
  • Operating Condition: 15ºC ~ 32 ºC (59 ºF ~ 89.6 ºF) , 10-90 % R.H.
  • Storage Condition: Refrigerator Temperature : 2ºC ~ 8ºC (35.6ºF ~ 46.4ºF) , 10-90 % R.H.
    Room Temperature : 8°C to 25°C (46.4°F to 77°F) , 10-90 % R.H."
  • Units Per Carton: 160 units - 20 units/box , 8 box/carton
  • Carton Size: L450 x W280 x H280mm
  • Gross Weight Per Carton: 8kg

More Less

Product category: Analyser systems / equipment, Glucose testing, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-4258 POCT Blood Glucose Monitoring System

FEATURES
• Strip eject function
• USB data transmission
• Embedded barcode scanner
• Flexible Memory Capacity: 1000 Measurement Results, 2000 Operator ID, 500 QC
• Data Management and Analysis Supported by U-Right POCT Management System

SPECIFICATIONS
  • Enzyme Type: GDH-FAD
  • Sample Size: 1.0 μL
  • Reaction Time: 5 seconds
  • Measurement Range: 10~600mg/dL (0.55~33.3mmol/L)
  • Hematocrit Range: 0 ~ 70%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
    CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy: ±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
  • Ketone Warning: Yes
  • Communication: Mini-USB
  • Power Source: Li-ion Rechargeable Battery
  • Memory Capacity: 1000 Measurement Results, 2000 Operator ID, and 500 QC
  • Dimension: 122 (L) x 64 (W) x 24 (H) mm
  • Weight: 130g (Without Battery)
  • Operating Condition: 10ºC (50ºF) ~ 40ºC (104ºF)
  • Storage Condition: -20ºC (-4ºF) ~ 60ºC (140ºF) (Meter); 2ºC (35.6ºF) ~ 32ºC (89.6ºF) (Strip)
  • Units Per Carton: 30
  • Carton Size: 42.5 (L) x 32.5 (W) x 34.5 (H) mm
  • Cross Weight Per Carton: 12.5 kg

More Less

Product category: Other equipment for clinical chemistry

TD-4261 Lactate Monitoring System

FEATURES
• Strip eject function
• Mini USB communication
• TFT color screen

SPECIFICATIONS
  • Sample Size: 0.8 μL
  • Reaction Time: 5 seconds
  • Measurement Range: 0.3-22 mM
  • Hematocrit Range: 10% - 65%
  • Package: Single foil pack
  • Communication: Mini USB port
  • Power Source: Lithium-ion battery rechargeable
  • Memory Capacity: 450 sets
  • Dimension: 96 (L) x 61 (W) x 26 (H) mm
  • Weight: 67.2 g
  • Operating Condition: strip / meter: +10°C (50°F) ~ 40°C (104°F)
  • Storage Condition: strip: 2°C (35.6°F) ~ 30°C (86°F) / meter: -20°C (-4°F) ~ 60°C (140°F)
  • Units Per Carton: 30
  • Carton Size: 340 (L) x 290 (W) x 383 (H) mm
  • Cross Weight Per Carton: 11.1 kg

More Less

Product category: Other equipment for clinical chemistry

TD-4141 Uric Acid Monitoring System

SPECIFICATIONS
  • Sample Size: 0.5 μL
  • Reaction Time: 15 seconds
  • Measurement Range: 3~20 mg/dL (178-1190 μM)
  • Precision: CV < 7.5%
  • Accuracy: ±25%
  • Communication: Strip Port Communication
  • Power Source: AAA * 1
  • Memory Capacity: 1000 sets
  • Dimension: 97.8 (L) x 33.5 (W) x 18 (H) mm
  • Weight: 30g (Without Battery)
  • Operating Condition: 10ºC(50ºF)~40ºC(104ºF)
  • Storage Condition: Meter: -20ºC(-4ºF) ~ +60ºC(140ºF)
    Strip: 2ºC(35.6ºF)~30ºC(86.0ºF)
  • Units Per Carton: 30
  • Carton Size: 340 (L) x 290 (W) x 383 (H) mm
  • Cross Weight Per Carton: 11.1 kg

More Less

Product category: Glucose testing, Other equipment for clinical chemistry

TD-4289 Multi-Functional Monitoring System - Glucose / Ketone / Lactate

SPECIFICATIONS
Meter
  • Ketone Warning: Yes
  • Communication: Bluetooth or Micro USB (HID)
  • Power Source: 2 x AAA
  • Memory Capacity: 1000 sets
  • Day Average: 7, 14, 21, 28, 60, 90 days for blood glucose
  • Daily Alarm: 4 daily alarms
  • Dimension: 96.3 (L) x 61 (W) x 22 (H) mm
  • Weight: 58.3g (Without Battery)
  • Operating Condition: 8°C(46.4°F)~45°C(113°F), below 90% R.H.
  • Storage Condition: -20 ºC ~ +60 ºC (Meter); 2ºC ~ 30ºC (Strip)
Glucose
  • Enzyme Type: GDH-FAD
  • Sample Size: 0.5 μL
  • Reaction Time: 5 seconds
  • Measurement Range: 10~800 mg/dL (0.56~44.4 mmol/L)
  • Hematocrit Range: 0% - 70%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100 mg/dL (5.55 mmol/L);
    CV < 5% at 100 mg/dL (5.55 mmol/L)
  • Accuracy: ±15 mg/dL if < 100 mg/dl;±15% if ≧ 100 mg/dL
  • Package: Vial pack / Single foil pack
Ketone
  • Sample Size: 0.8 μL
  • Enzyme Type: HBD
  • Reaction Time: 10 seconds
  • Measurement Range: 0.1 ~ 8.0 mmol/L
  • Hematocrit Range: 10% - 70%
  • Precision: ≦1 mmol/L, SD < 0.1 mM; > 1 mmol/L, CV < 7.5%
  • Package: Vial pack / Single foil pack
Lactate
  • Sample size: 0.8uL
  • Reaction time: 5 seconds
  • Measurement Range: 0.3 - 22 mmol/L
  • Hematocrit Range: 10% - 65%
  • Precision: CV < 7.5%
  • Package: Single foil pack

More Less

Product category: Glucose testing, Other equipment for clinical chemistry, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-4140 Smartphone Dongle - Glucose / Ketone / Cholesterol

SPECIFICATIONS
Types                                        Strip I                                             Strip II                                         Strip III
Parameter                             Glucose                                          Ketone                                         Cholesterol
Sample size                          1.0 μL                                              1.0 μL                                            3.0 μL
Reaction time                      5 seconds                                      10 seconds                                 60 seconds
Measurement Range        10~700 mg/dL                             0.1 ~ 8.0 mmol/L                     100~400 mg/dl
                                                   (0.56~38.89mmol/L)
Hematocrit Range              0 ~ 70%                                         10 ~ 70%                                     20 ~ 60%
Precision                                CV < 5%                                         ≦1mmol/L, SD<0.1mM;       CV<7.5%
                                                                                                             >1mmol/L, CV<7.5%
Package                                  Vial pack                                       Single foil pack                        Single foil pack

More Less

Product category: Glucose testing

TD-4206A MULTI-FUNCTIONAL MONITORING SYSTEM - Glucose / Ketone / Cholesterol

SPECIFICATIONS

Meter
Ketone Warning: Yes
Communication: Strip port
Power Source: 2 x AAA
Memory Capacity: 1000 sets
Day Average: 7, 14, 21, 28, 60, 90 days for blood glucose
Daily Alarm: 4 daily alarms
Dimension: 97 (L) x 62.2 (W) x 28.9 (H) mm
Weight: 67.5 g (without battery)
Operating Condition: 10°C ~ 40°C, below 85% R.H.
Storage Condition: -20 ºC ~ +60 ºC (Meter); 2ºC ~ 32ºC (Strip)

Glucose
Enzyme Type: GDH-FAD
Sample Size: 0.8 μL
Reaction Time: 5 seconds
Measurement Range: 10 - 700 mg/dL (0.56 - 38.89 mmol/L)
Hematocrit Range: 0% - 70%
Precision: SD < 5mg/dL (0.278mmol/L) if < 100mg/dL (5.56mmol/L); CV < 5% if ≥ 100mg/dL (5.56 mmol/L)
Accuracy: ≤ ±15mg/dL if < 100mg/dL; ≤ ±15% if ≥ 100mg/dL
Package: Vial pack

Ketone
Sample Size: 1.0 μL
Reaction Time: 10 seconds
Measurement Range: 0.1 ~ 8.0mmol/L
Hematocrit Range: 10% - 70%
Precision: ≤ 1mmol/L, SD < 0.1mM; > 1mmol/L, CV < 7.5%
Package: Single foil pack

Cholesterol
Sample size: 3.0 μL
Reaction time: 60 seconds
Measurement Range: 100 ~ 400 mg/dL
Hematocrit Range: 20% - 60%
Precision: CV < 7.5%
Package: Single foil pack

More Less

Product category: Glucose testing

TD-4279C/D MULTI- FUNCTIONAL MONITORING SYSTEM - Glucose / Ketone

SPECIFICATIONS

Meter
Ketone Warning: Yes
Communication: Strip port (TD-4279C) / Bluetooth (TD-4279D)
Power Source: 2 x AAA
Memory Capacity: 1000 sets
Day Average: 7, 14, 21, 28, 60, 90 days for blood glucose
Daily Alarm: 4 daily alarms
Dimension: 97 (L) x 62.2 (W) x 28.9 (H) mm
Weight: 67.5 g (without battery)
Operating Condition: 10°C ~ 40°C, below 85% R.H.
Storage Condition: 20 ºC ~ +60 ºC (Meter); 2ºC ~ 32ºC (Strip)

Glucose
Enzyme Type: GDH-FAD
Sample Size: 1.0 μL
Reaction Time: 5 seconds
Measurement Range: 10 - 700 mg/dL (0.56 - 38.89 mmol/L)
Hematocrit Range: 0% - 70%
Precision: CV < 5% if > 100 mg/dL; SD < 5 mg/dL if ≤ 100 mg/dL
Accuracy: ±15 mg/dL if ≤ 100 mg/dL; ±15% if > 100 mg/dL
Package: Vial pack

­β-Ketone
Sample Size: 1.0 μL
Reaction Time: 10 seconds
Measurement Range: 0.1 ~ 8.0 mmol/L
Hematocrit Range: 10% - 70%
Precision: ≤ 1 mmol/L, SD < 0.1 mM; > 1 mmol/L, CV < 7.5%
Package: Single foil pack

More Less

Product category: Glucose testing, Other equipment for clinical chemistry, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-4257 BLOOD GLUCOSE PLUS B-KETONE MONITORING SYSTEM - Glucose / Ketone

SPECIFICATIONS

Meter
Part No.: TD-4257A (RS232) / TD-4257B (Bluetooth)
Communication: RS232 / Bluetooth communication
Ketone Warning: Yes
Power Source: 2 x AAA
Memory Capacity: 1000 sets
Day Average: 7, 14, 21, 28, 60, 90 days for blood glucose
Daily Alarm: 4 daily alarms
Dimension: 96 (L) x 61 (W) x 26 (H) mm
Weight: 81g (without battery)
Operating Condition: 10ºC (50ºF) ~ +40ºC (104ºF), 10% ~ 85% R.H.
Storage Condition: -20 ºC ~ +60 ºC (Meter); 2ºC ~ 30ºC (Strip)

Strip
Strip Type: Glucose
Enzyme Type: GDH-FAD
Sample Size: 0.5 μL
Reaction Time: 5 seconds
Measurement Range: 20 ~ 650 mg/dL (1.1~36.1mmol/L)
Hematocrit Range: 20% ~ 65%
Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100 mg/dL (5.55 mmol/L); CV < 5% at 100 mg/dL (5.55 mmol/L)
Accuracy: ±15 mg/dL if < 100 mg/dL; ±15% if ≥ 100 mg/dL
Package: Vial pack / Single foil pack

Strip Type: Ketone
Enzyme Type: HBD
Sample Size: 1.0 μL
Reaction Time: 10 seconds
Measurement Range: 0.1 ~ 8.0 mmol/L
Hematocrit Range: 20% ~ 65%
Precision: ≤ 1 mmol/L, SD < 0.1 mM; > 1 mmol/L, CV < 7.5%
Accuracy: ≤ 1 mmol/L, SD < 0.1 mM; > 1 mmol/L, CV < 7.5%
Package: Vial pack / Single foil pack

More Less

Product category: Glucose testing

TD-4277C BLOOD GLUCOSE MONITORING SYSTEM

SPECIFICATIONS

Enzyme Type: GDH-FAD
Sample Size: 0.5 μL
Reaction Time: 5 sec
Measurement Range: 20 ~ 650 mg/dL (1.1~36.1mmol/L)
Hematocrit Range: 20% - 65%
Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L); CV < 5% at 100mg/dL (5.55 mmol/L)
Accuracy: ±15mg/dL if < 100mg/dl;±15% if ≧ 100mg/dL
Ketone Warning: Yes
Communication: Mini USB (HID)
Power Source: AAA * 2
Memory Capacity: 1000 sets
Day Average: 7, 14, 21, 28, 60, 90 Days
Daily Alarm: 4 daily alarms
Dimension: 96 (L) x 61 (W) x 26 (H)mm
Weight: 67.2g (Without Battery)
Operating Condition: 10ºC(50ºF) ~ 40ºC(104ºF), below 85% R.H.
Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 2ºC(35.6ºF)~32ºC(89.6ºF) (Strip)
Units Per Carton: 30
Carton Size: 405 (L) x 390 (W) x 365 (H) mm
Cross Weight Per Carton: 12.2 kg

More Less

Product category: Glucose testing

TD-4183 BLOOD GLUCOSE MONITORING SYSTEM

SPECIFICATIONS

Enzyme Type: GDH-FAD
Sample Size: 0.5 μL
Reaction Time: 6 second
Measurement Range: 20 ~ 650mg/dL (1.1 ~ 36.1mmol/L)
Hematocrit Range: 20% - 65%
Precision: SD < 5mg/dL (0.278mmol/L) at < 100mg/dL (5.55mmol/L);
CV < 5% at 100mg/dL (5.55mmol/L)
Accuracy: ±15mg/dL if < 100mg/dL; ±15% if ≧ 100mg/dL
Ketone Warning: YES
Communication: Strip Port Communication
Power Source: AAA x 1
Memory Capacity: 1000 sets
Day Average: 7, 14, 21, 28, 60, 90 days
Daily Alarm: 4 daily alarms
Dimension: 90.3 (L) x 52.3 (W) x 18 (H) mm
Weight: 46.4 g (without battery)
Operating Condition: 8ºC (46.4ºF) ~ 45ºC (113ºF)
Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 2ºC (35.6ºF) ~ 30ºC (86.0ºF) (Strip)
Units per Carton: 30
Carton Size: 340 (L) x 290 (W) x 383 (H) mm
Cross Weight per Carton: 7.3 kg

More Less

Product category: Glucose testing

TD-4285 BLOOD GLUCOSE MONITORING SYSTEM

SPECIFICATIONS
Enzyme Type : GDH-FAD
Sample Size : 0.5 μL
Reaction Time : 6 seconds
Measurement Range : 20 ~ 650mg/dL (1.1 ~ 36.1mmol/L)
Hematocrit Range : 20%-65%
Precision : SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
: CV < 5% at 100mg/dL (5.55 mmol/L)
Accuracy : ±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
Ketone Warning : Yes
Communication : RS232
Power Source : CR2032 x 1
Memory Capacity : 450 sets
Day Average : 7, 14, 21, 28, 60, 90 days
Daily Alarm : 4 daily alarms
Dimension : 96 (L) x 60 (W) x 15 (H) mm
Weight : 41.2g (without battery)
Operating Condition : 10ºC (50ºF) ~ 40ºC (104ºF)
Storage Condition : -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter)
: 2ºC(35.6ºF)~30ºC(86.0ºF) (Strip)
Units Per Carton : 30
Carton Size : 476 (L) x 370 (W) x 400 (H) mm
Gross Weight Per Carton : 7.5 kg

More Less

Product category: Glucose testing

TD-5010 LANCING DEVICE and TWIST LANCET

SPECIFICATIONS

LANCING DEVICE
Model Number: TD-5010B
Penetration Depth Setting: 6-level comfort dial
Penetration Range: 0.8 mm to 1.8 mm
Dimension: 118.7 (L) x 17.5 (D) mm
Weight: 16.5 g
Priming of Device:
Push button to prime with status display window
Lancet Ejection: Yes
Alternative Site Testing: Yes

TWIST LANCET
Model Number: TD-5084A
Lancet Gauge: 30G
Weight: 0.4g
Dimension: 32.6mm x 6.4mm
Units per Carton: 100 pcs/box and 140 boxes/carton
Net Weight per Carton: 7.62 kg
Cross Weight per Carton: 8.62 kg

More Less

Product category: Glucose testing

TD-5011 LANCING DEVICE and TWIST LANCET

SPECIFICATIONS

LANCING DEVICE
Model Number: TD-5011
Penetration Depth Setting: 9-level comfort dial
Penetration Range: 0.4 mm to 1.5 mm
Dimension: 109 (L) x 18 (D) mm
Weight: 17 g
Priming of Device:
Push button to prime with status display window
Lancet Ejection: Yes
Alternative Site Testing: No

TWIST LANCET
Model Number: TD-5084A
Lancet Gauge: 30G
Weight: 0.4g
Dimension: 32.6mm x 6.4mm
Units per Carton: 100 pcs/box and 140 boxes/carton
Net Weight per Carton: 7.62 kg
Cross Weight per Carton: 8.62 kg

More Less

Product category: Glucose testing

TD-5052 AKTIVESAFE LANCET

FEATURES
• Easy to use
• Five different size 21G, 23G, 26G, 28G, 30G
• Penetration Depth 2.2, 2.2, 1.8, 1.8, 1.6 (mm)
• Single-use only
• Lancet automatic retraction

More Less

Product category: Glucose testing

TD-4280 BLOOD GLUCOSE MONITORING SYSTEM

SPECIFICATIONS
Enzyme Type : GDH-FAD
Sample Size : 0.5 μL
Reaction Time : 5 seconds
Measurement Range : 20 ~ 600mg/dL (1.1 ~ 33.3mmol/L)
Hematocrit Range : 35%-60%
Precision : SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
: CV < 5% at 100mg/dL (5.55 mmol/L)
Accuracy : ±15mg/dL if ≦100mg/dL; ±15% if >100mg/dL
Ketone Warning : Yes
Communication : RS232
Power Source : AAA x 2
Memory Capacity : 450 sets
Day Average : 7, 14, 21, 28, 60, 90 days
Daily Alarm : 4 daily alarms
Dimension : 95 (L) x 52 (W) x 20 (H) mm
Weight : 48.8 g (without battery)
Operating Condition : 10ºC(50ºF)~40ºC(104ºF)
Storage Condition : -20ºC(-4ºF) ~ +60ºC(140ºF) (Meter)
: 2ºC(35.6ºF)~32ºC(89.6ºF) (Strip)
Units Per Carton : 30
Carton Size : 405 (L) x 390 (W) x 365 (H) mm
Gross Weight Per Carton : 7.3 kg

More Less

Product category: Glucose testing

TD-4283 Blood Glucose monitoring

SPECIFICATIONS
Enzyme type: GDH-FAD
Sample Size: 0.5 µL
Reaction Time: 5 seconds
Measurement Range: 20 ~ 600mg/dL (1.1~33.3mmol/L)
Hematocrit Range: 35% - 60%
Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
                     CV < 5% at 100mg/dL (5.55 mmol/L)
Accuracy: ±15mg/dL if < 100mg/dL; ±15% if ≧ 100mg/dL
Communication: Strip Port Communication
Power Source: CR2032 x 1
Memory Capacity: 150 sets
Dimension: 43.5 (L) x 39.3 (W) x 24.2 (H) mm
Weight: 13g (Without Battery)
Operating Condition: +10ºC(50ºF) ~ +40ºC(104ºF), below 85% R.H.
Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter) ; 2ºC(35.6ºF)~32ºC(89.6ºF) (Strip)
Units Per Carton: 70
Carton Size: 585(L) x 330 (W) x 297 (H) mm
Cross Weight Per Carton: 11.3kg

SPECIFICATIONS-Accessories
  • ACC-001: Bluetooth dongle
  • ACC-002: USB cable

More Less

Product category: Glucose testing

TD-4287 BLOOD GLUCOSE MONITORING SYSTEM

SPECIFICATIONS
  • Enzyme Type: GDH-FAD
  • Sample Size: 0.5 µL
  • Reaction Time: 5 seconds
  • Measurement Range: 20 ~ 600mg/dL (1.1 ~ 33.3mmol/L)
  • Hematocrit Range: 35-60%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
                         CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy: ±15mg/dL if < 100mg/dL; ±15% if ≧ 100mg/dL
  • Communication: Mini USB
  • Power Source: CR2032 x 1
  • Memory Capacity: 150 sets
  • Dimension: 103.4 (L) x 28.1 (W) x 15.1 (H) mm
  • Weight: 31.8g (without battery)
  • Operating Condition: 10ºC (50ºF) ~ 40ºC (104ºF)
  • Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 2ºC (35.6ºF) ~ 32ºC (89.6ºF) (Strip)
  • Units Per Carton: 40
  • Carton Size: 520 (L) x 270 (W) x 363 (H) mm
  • Cross Weight Per Carton: 6 kg

More Less

Product category: Glucose testing

TD-4125 Blood Glucose Monitoring System

SPECIFICATIONS
  • Enzyme Type: GOD
  • Sample Size: 0.7 μL
  • Reaction Time: 7 seconds
  • Measurement Range: 20 ~ 600mg/dL (1.1 ~ 33.3mmol/L)
  • Hematocrit Range: 30% - 55%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L); CV < 5% at 100mg/dL (5.55mmol/L)
  • Accuracy: ±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
  • Ketone Warning: YES
  • Communication: RS232-4 Poles
  • Power Source: AAA x 2
  • Memory Capacity: 450 sets
  • Day Average: 7, 14, 21, 28, 60, 90 Days
  • Daily Alarm: 4 daily alarms
  • Dimension: 97 (L) x 52 (W) x 16 (H) mm
  • Weight: 47.8 g (without battery)
  • Operating Condition: 10ºC (50ºF) ~ 40ºC (104ºF), below 85% R.H.
  • Storage Condition: -20ºC (-4ºF) ~ 60ºC (140ºF) (Meter) ; 4ºC(35.6ºF) ~ 40ºC(86.0ºF) (Strip)
  • Units Per Carton: 30
  • Carton Size: 340 (L) x 290 (W) x 383 (H) mm
  • Cross Weight Per Carton: 8.05 kg


More Less

Product category: Glucose testing

TD-4265 Blood Glucose Monitoring System

SPECIFICATIONS
  • Enzyme Type: GOD
  • Sample Size: 0.5 μL
  • Reaction Time: 5 seconds
  • Measurement Range: 20 ~ 600mg/dL (1.1 ~ 33.3mmol/L)
  • Hematocrit Range: 30%-55%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L); CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy: ±15mg/dL if ≦100mg/dL; ±15% if >100mg/dL
  • Communication: Mini-USB
  • Power Source: CR2032 * 1
  • Memory Capacity: 150 Sets
  • Dimension: 125 (L) x 33 (W) x 14 (H) mm
  • Weight: 39.8 g (without battery)
  • Operating Condition: 10ºC (50ºF) ~ 40ºC (104ºF)
  • Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 4ºC (39.2ºF) ~ 40ºC (104ºF) (Strip)
  • Units Per Carton: 40
  • Carton Size: 430 (L) x 360 (W) x 230 (H) mm
  • Cross Weight Per Carton: 10.4 kg

More Less

Product category: Glucose testing

TD-4267 Blood Glucose Monitoring System

SPECIFICATIONS
  • Enzyme Type: GOD
  • Sample Size: 0.5 μL
  • Reaction Time: 5 seconds
  • Measurement Range: 20 ~ 600mg/dL (1.1 ~ 33.3mmol/L)
  • Hematocrit Range: 30%-55%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L); CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy: ±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
  • Ketone Warning: Yes
  • Communication: Mini USB
  • Power Source: CR2032 * 1
  • Memory Capacity: 450 Sets
  • Day Average: 7,14,21,28,60,90 Days
  • Daily Alarm: 4 daily alarms
  • Dimension: 90.0 (L) x 55.0 (W) x 18.0 (H) mm
  • Weight: 49g (Without Battery)
  • Operating Condition: 10ºC (50ºF) ~ 40ºC (104ºF)
  • Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 4ºC (39.2ºF) ~ 40ºC (104ºF) (Strip)
  • Units Per Carton: 30
  • Carton Size: 397 (L) x 385 (W) x 436 (H) mm
  • Cross Weight Per Carton: 12.7 kg

More Less

Product category: Glucose testing

TD-4268 Blood Glucose Monitoring System

SPECIFICATIONS
  • Enzyme Type: GDH
  • Sample size: 1.0 μL
  • Reaction time: 5 seconds
  • Measurement range: 10 ~ 600mg/dL (0.55 ~ 33.3mmol/L)
  • Hematocrit Range: 0% - 70%
  • Precision: SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L); CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy: ±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
  • Ketone Warning: YES
  • Communication: RS232
  • Power Source: AAA x 2
  • Memory Capacity: 1000 sets
  • Day Average: 7, 14, 21, 28, 60, 90 days
  • Daily Alarm: 4 daily alarms
  • Dimension: 95 (L) x 55 (W) x 20 (H) mm
  • Weight: 76.2g (Without Battery)
  • Operating Condition: +10ºC(50ºF) ~ +40ºC(104ºF), below 85% R.H.
  • Storage Condition: -20ºC(-4ºF) ~ +60ºC(140ºF) (Meter) ;2ºC(35.6ºF)~30ºC(89.6ºF) (Strip)
  • Units Per Carton: 30
  • Carton Size: 405 (L) x 390 (W) x 365 (H) mm
  • Cross Weight Per Carton: 6.8 kg

More Less

Product category: Glucose testing

TD-4239 Blood Glucose Monitoring System

SPECIFICATIONS
  • Enzyme Type: GDH-FAD
  • Sample Size: 1.0 μL
  • Reaction Time: 5 seconds
  • Measurement Range: 10 ~ 600mg/dL (0.55 ~ 33.3mmol/L)
  • Hematocrit Range: 0-70 %
  • Precision: SD < 5mg/dL (0.278mmol/L) at < 100mg/dL (5.55mmol/L); CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy:  ±15mg/dL if ≦100mg/dL; ±15% if >100mg/dL
  • Communication: RS232
  • Power Source: CR2032 x1
  • Memory Capacity: 400 sets
  • Day Average: 7, 14, 21, 28, 60, 90 days
  • Daily Alarm: 4 daily alarms
  • Dimension: 96 (L) x 49.0 (W) x 14.0 (H) mm
  • Weight: 42 g (without battery)
  • Operating Condition: +10ºC (50ºF) ~ +40ºC (104ºF), below 85 % R.H.
  • Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 2ºC (35.6ºF) ~ 30ºC (89.6ºF) (Strip)
  • Units Per Carton: 30
  • Carton Size: 476 (L) x 370 (W) x 400 (H) mm
  • Gross Weight Per Carton: 10.5 kg

More Less

Product category: Analyser systems / equipment

TD-4235 VET ß-KETONE MONITORING SYSTEM

SPECIFICATIONS
  • Enzyme Type: β-Hydroxybutyrate Dehydrogenase
  • Sample Size: 0.7 µL
  • Reaction Time: 5 seconds
  • Measurement Range: 0.1 ~ 8.0mmol/L (1.04 ~ 83.2mg/dL)
  • Precision: ≦ 2mmol/L, SD < 0.2mM; > 2mmol/L, CV < 7.5%
  • Accuracy: ±0.5mmol/L if ≦ 2mmol/L; ±25% if > 2mmol/L
  • Communication: Mini USB
  • Power Source: AAA x 1
  • Memory Capacity: 150 sets
  • Dimension: 93 (L) x 36 (W) x 21.3 (H) mm
  • Weight: 45.4g (without battery)
  • Operating Condition: 10ºC (50ºF) ~ +40ºC (104ºF), below 85% R.H.
  • Storage Condition: -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 2ºC (35.6ºF) ~ 30ºC (86.0ºF) (Strip)
  • Units Per Carton: 42
  • Carton Size: 476 (L) x 370 (W) x 400 (H) mm
  • Cross Weight Per Carton: 13.5 kg

More Less

Product category: Analyser systems / equipment

TD-5220 Plasma Calcium Monitoring System

SPECIFICATIONS
  • Sample Size:  45μL ±5 μL
  • Reaction Time:  180 seconds
  • Measuring Range:  0.5 to 3.0 mmol/L
  • Precision: < 7.5%
  • Accuracy:  ±25%
  • Communication:  RS232
  • Power Source:  AAA x 2
  • Memory Capacity:  300 sets
  • Dimension:  166.1 (L) x 34.9 (W) x 34.9 (H) mm
  • Weight:  81 g (without battery)
  • Operating Condition:  2 ºC ~ 35 ºC
  • Storage Condition:  -20ºC (-4ºF) ~ +60ºC (140ºF) (Meter); 2ºC (35.6ºF) ~ 32ºC (89.6ºF) (Strip)
  • Units Per Carton:  50
  • Carton Size:  38 (L) x 21 (W) x 35.5 (H) cm
  • Cross Weight Per Carton:  10.5 kg

More Less

Product category: Blood pressure monitoring equipment

TD-3223 Blood Pressure and Blood Glucose Monitor

SPECIFICATIONS
  • Power Source:  2 x AAA
  • Memory Capacity:  450 sets
  • Communication:  Bluetooth smart (TD-3223D) / RS232(TD-3223B)
  • Battery Life:  At least 200 measurements
  • Power Saving:  180 seconds
  • Size of Monitor w/o Cuff:  75(L) x 37.5(W) x 60.5(H) mm, 135g (Without battery)
  • Operating Condition:  5°C ~ 40°C, Humidity 15% ~ 93%
BLOOD GLUCOSE MONITOR
  • Enzyme Type:  GOD
  • Sample Size / Reaction Time:  0.7 μL / 7 seconds
  • Measurement Range:  20 ~ 600 mg/dL (1.1 ~ 33.3 mmol/L)
  • Hematocrit Range:  30% ~ 55%
  • Precision:  SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
  •                       CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy:  ±15mg/dL if ≤100mg/dL; ±15% if > 100 mg/dL
BLOOD PRESSURE MONITOR
  • Accuracy of Pressure:  ±3 mmHg or ±2% of reading
  • Accuracy of Heart Rate:  ±4% of reading
  • Measurement Range:  Systolic : 60 ~ 255 mmHg / Diastolic : 30 ~ 195 mmHg
  •                                              Pulse rate : 40 ~ 199 / minute
  • Units per Carton:  30
  • Net Weight per Carton:  21.4 kg
  • Gross Weight per Carton:  22.4 kg
  • Carton Size:  L48 x W39 x H42 cm

More Less

Product category: Blood pressure monitoring equipment

TD-3261 Blood Pressure and Blood Glucose Monitor

SPECIFICATIONS
  • Power Source:  Rechargeable Li-Ion Battery and External DC 6V
  • Memory Capacity:  Maximum 864 memory records
  • Communication:  Bluetooth smart (TD-3261B) / GPRS (TD-3261G)
  • Power Saving:  180 seconds
  • Size of Monitor w/o Cuff:  147mm (L) x 105mm (W) x 80mm (H), 500g (include battery)
  • Operating Condition:  10°C~40°C
BLOOD GLUCOSE MONITOR
  • Enzyme type:  GOD
  • Sample Size / Reaction Time:  0.5 μL  / 5 seconds
  • Measurement Range:  20~600 mg/dL (1.1~33.3 mmol/L)
  • Hematocrit Range:  20% ~ 60%
  • Precision:  SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);
  •                      CV < 5% at 100mg/dL (5.55 mmol/L)
  • Accuracy:  ±15mg/dL if 100 mg/dL; ±15% if > 100 mg/dL
  • Ketone Warning:  Yes
BLOOD PRESSURE MONITOR
  • Accuracy of Pressure:  ±3 mmHg or ±2% of reading
  • Accuracy of Heart Rate:  ±4% of reading
  • Measurement Range:  Systolic : 60 ~ 250 mmHg / Diastolic : 30 ~ 180 mmHg
  •                                              Pulse rate : 40 ~ 199 / minute
  • Units per Carton:  12
  • Net Weight per Carton:  11.36 kg
  • Gross Weight per Carton:  12.36 kg
  • Carton Size:  L42.5 x W37.0 x H34.5 cm

More Less

Product category: Blood pressure monitoring equipment, Analyser systems / equipment, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-3140 Upper Arm Blood Pressure Monitor

SPECIFICATIONS
  • Accuracy of Pressure:  ±3 mmHg or ±2% of reading
  • Accuracy of Heart Rate:  ±4% of reading
  • Measurement Range:  Systolic: 60 ~ 255 mmHg / Diastolic: 30 ~ 195 mmHg
    Pulse rate: 40~199 / minute
  • Memory Capacity:  200 sets
  • Communication:  Bluetooth smart
  • Power Source:  4 x AAA
  • Dimension:  145 (L) x 64.5 (W) x 29.6 (H) mm
  • Weight:  240 g (without battery)
  • Operating Condition:  5 ºC ~ 40 ºC; Humidity 15% ~ 93%
  • Battery Life:  At least 200 measurements
  • Power Saving:  180 seconds
  • Backlight:  LCD backlight
  • Units per Carton:  30
  • Net Weight per Carton:  12.63 kg
  • Gross Weight per Carton:  13.63 kg
  • Carton Size:  L42 x W39 x H41 cm
  • Cuff Size:  Wide Range: 24 ~ 43 cm, M Size: 24 ~ 35 cm

More Less

Product category: Blood pressure monitoring equipment

TD-3124 Blood Pressure Monitoring System

SPECITATIONS
  • Accuracy of Pressure: ±3 mmHg or ±2% of reading
  • Accuracy of Heart Rate: ±4% of reading
  • Measurement Range: Systolic : 60 ~ 255 mmHg / Diastolic : 30 ~ 195 mmHg
                                                                   Pulse rate : 40~199 / minute
  • Power Source: 4 x AA or 6V DC adaptor (optional )
  • Dimension: 130.5 (L) x 90 (W) x 55 (H) mm
  • Weight: 210 g (without battery)
  • Operating Condition: 5 ºC ~ 40 ºC ; Humidity 15% ~ 93%
  • Battery Life: At least 500 measurements
  • Power Saving: 180 seconds
  • Units per Carton: 30
  • Net Weight per Carton: 10.8 kg
  • Gross Weight per Carton: 11.8 kg
  • Carton Size: 42.5 x 32.5 x 34.5 cm

More Less

Product category: Blood pressure monitoring equipment

TD-3127 BLOOD PRESSURE MONITORING SYSTEM

SPECIFICATIONS
  • Accuracy of Pressure:  ±3 mmHg or ±2% of reading
  • Accuracy of Heart Rate:  ±4% of reading
  • Measurement Range:  Systolic : 60 ~ 255 mmHg / Diastolic : 30 ~ 195 mmHg
  •                                              Pulse rate : 40~199 / minute
  • Memory Capacity:  100 sets
  • User Number:  4 sets
  • Power Source:  4 x AA or 6V DC Adaptor (Optional)
  • Dimension:  150 (L) x 96 (W) x 66 (H) mm
  • Weight:  150 g (without battery)
  • Operating Condition:  5 ºC ~ 40 ºC ; Humidity 15% ~ 93%
  • Battery Life:  At least 300 measurements
  • Power Saving:  180 seconds
  • Units per Carton:  30
  • Net Weight per Carton:  8.9 kg
  • Gross Weight per Carton:  9.9 kg
  • Carton Size:  47.3 x 35.8 x 41.5 cm


More Less

Product category: Blood pressure monitoring equipment

TD-3128 Blood pressure monitoring system

SPECIFICATIONS
  • Accuracy of Pressure : ±3 mmHg or ±2% of reading
  • Accuracy of Heart Rate: ±4% of reading
  • Measurement Range: Systolic : 60 ~ 255 mmHg / Diastolic : 30 ~ 195 mmHg
  •                                              Pulse rate : 40~199 / minute
  • Memory Capacity: 400 sets
  • Data Output: USB (TD-3128A) / Bluetooth (TD-3128B)
  • User Number: 4 sets
  • Power Source: 4 x AA or 6V DC Adaptor (Optional)
  • Dimension: 141 (L) x 121 (W) x 72 (H) mm
  • Weight: 350 g (without battery)
  • Operating Condition: 5 ºC ~ 40 ºC ; Humidity 15% ~ 93%
  • Battery Life: At least 200 measurements
  • Power Saving: 180 seconds
  • Units per Carton: 12
  • Net Weight per Carton: 15.7 kg
  • Gross Weight per Carton: 16.7 kg
  • Carton Size: 47.3 x 35.8 x 41.5 cm

More Less

Product category: Inhaler and aerosol appliances

TD-7013 Compressor Nebulizer

SPECIFICATIONS
  • Particle Size:   MMAD approx. 3 um
  • Nebulizer Rate:   >0.35 ml/min
  • Medication Capacity:   6mL
  • Power Consumption:   12W
  • Power Source:   12V DC (Switch power universal adapter)
  • Dimension:   125 x 115 x 46 mm
  • Weight:   220g
  • Operating Condition:   5ºC ~ 40ºC; RH 15% ~ 93%
  • Storage Condition:   -25ºC ~ 70ºC; RH 10% ~ 95%
  • Units per Carton:  20
  • Net Weight per Carton:   12 kg
  • Gross Weight per Carton:   13 kg
  • Carton Size:   57 x 33 x 39 cm

More Less

Product category: Inhaler and aerosol appliances

TD-7001 Vibrating Mes Nebulizer

SPECIFICATIONS
  • Particle Size:  MMAD approx. 3 microns
  • Nebulization Rate:  ≧ 0.2ml/min
  • Medication Capacity:  10 mL
  • Power Source:  2 x AA alkaline batteries or 6V power adaptor (Optional)
  • Power Consumption:  ≥ 1.5W
  • Dimension:  74D / 126H (mm)
  • Weight:  100 g
  • Unit per Carton:  24 sets

More Less

Product category: Inhaler and aerosol appliances

TD-7014 Portable Compressor Nebulizer

SPECIFICATIONS
  • Particle Size:  Approx. 3 microns
  • Nebulization Rate:  ≥ 0.25mL/min
  • Operating Pressure Range:  35~69kPa (5~10 Psi)
  • Medication Capacity:  6mL
  • Power Consumption:  6W
  • Power supply:  AC adaptor or 4 x AA battery (Alkaline or rechargeable)
  • Waterproof grade:  IP22
  • Dimension:  115L / 85W / 207H (mm)
  • Weight:  205g (without batteries)
  • Units Per Carton:  24 PCS
  • Carton Size:  L523 x W493 x H376 mm
  • Cross Weight Per Carton:  12 KGS

More Less

Product category: Devices for measuring body temperature / thermometer, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-1107 EAR INFRARED THERMOMETER

  • Measurement Range: 32.0°C (89.6°F) ~43.0°C(109.4°F)
  • Measurement Units: °C or °F Switchable
  • Probe Cover Detector: Equipped with Auto power-on function
  • Battery life: At Least 3000 Measurements
  • Memory Capacity: 10 Measurements
  • Communication: Bluetooth Smart (optional)

More Less

Product category: Devices for measuring body temperature / thermometer, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-1241 Non-Contact Forehead Thermometer

SPECIFICATIONS
  • Dimension:  150 (L) x 48.5 (W) x 55 (H)mm
  • Weight:  125.8 g (With Battery)
  • Resolution:  0.1°C/0.1°F
  • Measurement Range:  Forehead: 22°C-44°C
                                                 Surface: 0°C -100°C
                                                 Room: 10°C -40°C
  • Accuracy:  Forehead: 36°C-39°C±0.2°C(22°C-35.9°C, 39.1°C -44°C±0.3°C)
    Surface/Room: ±.1°C
  • Communication:  No Data Transmission (TD-1241A) / Bluetooth smart (TD-1241B)
  • Measurement Units:  °C(preset)/ °F
  • Power source:  2*1.5V AA
  • Battery life:  > 3000 measurements
  • Memory:  30 measurements
  • Power saving:  30 seconds
  • Operating condition:  10°C to 40°C (50°F to 104°F), 95% RH or less (non-condensing)
  • Storage/Transportation condition:  -20°C to 60°C (-4°F to 140°F), 95% RH or less (non-condensing)
  • Measuring Distance:  3-7cm
  • Units per Carton:  30
  • Net Weight per Carton:  7.5kg
  • Gross Weight per Carton:  8.5kg
  • Carton Size:  42x39x41cm

More Less

Product category: Devices for measuring body temperature / thermometer, Analyser systems / equipment, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-1115 Non-Contact Forehead Thermometer

  • Non-Contact infrared Thermometer
  • Forehead and Room temperature
  • 3 Colors Backlight Indicator

More Less

Product category: Devices for measuring body temperature / thermometer, Analyser systems / equipment, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-1035 Wearable Bluetooth Thermometer

  • Measurement Range: 20.00°C (68.00°F) ~ 45.00°C(113.00°F)
  • Measurement Unit: °C or °F Switchable
  • Power Source: CR2032
  • Battery Life: 200 hours
  • Communication: Bluetooth
  • Bluetooth Distance: Maximum 10M

More Less

Product category: Analyser systems / equipment, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-2555 Weight Scale

  • Body mass index function
  • Age, height, and gender for more precise algorithm
  • Large LCD with backlight
  • Automatically power-off function

More Less

Product category: mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI), Analyser systems / equipment

TD-2202 Portable ECG recorder

  • 3.5” color touch screen
  • 5 leads ECG recorder with event recording function
  • Analyzes PHC (Personal Health Care) data
  • Direct view of 4 channel ECG waveform
  • Displays messages concerning heart rate
  • Bluetooth communication

More Less

Product category: Devices for measuring body temperature / thermometer, Blood pressure monitoring equipment, Analyser systems / equipment, Glucose testing, Other equipment for clinical chemistry

TD-2300 Vital Sign Monitor

SPECIFICATIONS
NIBP
  • Cuff Pressure Range : 0-300 mmHg
  • Measurement Method : Adult mode (Clever Inflation or Deflation)
                                                    Pediatric mode (Clever Inflation or Deflation)
                                                    Neonate mode (Deflation Only)
  • Pressure Accuracy : ±3 mmHg over full range
  • Automatic : Cycles OFF, 5min, 10min, 15min, 30min, 1hr, 1.5hr, 2hr, 4hr
  • Pulse Rate Range : 30 - 240 bpm
  • Pulse Accuracy : ± 2% or ± 1 bpm when HR < 70 bpm
SpO2 Monitor
  • SpO2 Measuring Range : 35 - 100%
  • SpO2 Accuracy : 80 - 100%, ±2%; 70-79%, ±3%; <70%, no denition
  • Pulse Measuring Range : 30 - 250 bpm
  • Pulse Range : ±1 bpm or ±1% when HR < 100 bpm
  • Measuring Principles : Dual wavelength LED
  • Audio : Tone with each detected pulse; pitch varies with saturation
ECG Monitor
  • Vertical Scales : 5, 10 mm/mV
  • Sweep Speed : 25 or 50 mm/sec (Selectable for Print out only)
  • DC Offset Correction : ± 300mV
  • Signal Sampling Resolution : 300 samples/sec (with 12-bit ADC)
  • Pulse Measuring Range : 30 - 250 bpm
  • Pulse Accuracy : ±1 bpm or ±1% when HR < 100 bpm
  • Defibrillation Proof : Yes
Blood Glucose
  • Measurement Range :10 - 600 mg/dL
  • Interface: IrDA communicate with main unit
  • HCT Compensation: 0 - 70%
  • Blood Volume: 1 μL
  • Enzyme: GDH-FAD
Ear Temperature
  • Measurement Type :Ear Thermometer
  • Interface :IrDA communicate with main unit
  • Measurement Range :32°C - 43°C
  • Accuracy :± 0.2° C
Mechanical
  • Dimension: 190 (L) x 190 (W) x 309 (H)mm
  • Weight: 2.5 Kg( including accessory and battery)
  • Mounting Option: Rolling Stand and Wall Mount

More Less

Product category: Other equipment for clinical chemistry, mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI)

TD-8201 Handheld Pulse Oximeter

SPECIFICATIONS

  • SpO2 Display Range: 0-100%
  • SpO2 Resolution: 1%
  • SpO2 Accuracy: 80-100%, ±2%; 70-79%, ±3%; <70%, no definition
  • SpO2 Method: Dual Wavelength LED
  • Pulse Rate Measuring Range: 30 - 250 bpm
  • Pulse Rate Accuracy: ±1 bpm or ±1% when HR < 100 bpm
  • Mode of Operation: Continues
  • LED Display:SpO2: 3 Digits, HR: 3 Digits, Pulse-Strength Bar
  • Status Indicate: Probe Good, Battery Status
  • Data Transmission: Bluetooth
  • Perfusion Index: 10-bar indicator
  • Alarm Range Setting:SpO2 High/Low , Pulse Rate High/Low
  • Pulse Volume Adjust: 2 Level or Off
  • LED Light Adjust: 2 Level
  • Power Source:AA Alkaline Battery x 4
  • Battery Usage Life:40 hours
  • Dimension: 140 (L) x 70 (W) x 32 (H)mm
  • Weight: 240g (with batteries)
  • Storage/Transportation Condition: -20ºC-60ºC; below 95% RH, non-condensing
  • Operating Condition: 10ºC-40°C; below 95% RH, non-condensing
  • Degree of Protection: Type BF
  • Water-Resistance: Against Water Splash, IPX2
  • Mechanical Impact-Resistance: Against Repeat Impact from 1 M Height
  • EMC Standard: EN60601-1-2
  • Safety Standard: EN60601-1
  • Performance Standard: ISO 80601-2-61

More Less

Product category: mHealth, mobile IT, wireless technologies (Bluetooth, WI-FI), Analyser systems / equipment

TD-8255 Fingertip Pulse Oximeter

SPECIFICATIONS
  • Dimension: 63 (L) x 35 (W) x 32 (H) mm
  • Weight: 40g (without battery)
  • Heart Rate Range: 30 ~ 250 beats per minutes (bpm)
  • SpO2 Range: 0% ~ 100%
  • Accuracy (SpO2): 80%~100% ±2 digits
  • Method: Dual wavelength LED
  • Perfusion Index: 5-bar indicator
  • Accuracy (Heart rate): ±1 bpm or ±1% whichever is greater
  • Power Source: 2 x AAA
  • Time to power saving: 15 seconds after removing finger
  • Backlight: LCD backlight
  • Communication: Bluetooth
  • Operating Temperature: 10ºC ~ 40ºC
  • EMC Standard: IEC60601-1-2
  • Safety Standard: IEC60601-1
  • Performance Standard: ISO80601-2-61
  • Unit per Carton: 80
  • Net Weight per Carton: 11.2kgs
  • Gross Weight per Carton: 12.5kgs
  • Carton Size: 518 (L) x 423 (W) x 300 (H) mm

More Less

Product category: Analyser systems / equipment

TD-8250 Finger Type Pulse Oximeter

SPECIFICATIONS

Pulse Oximetry
  • Range: 0% to 100%
  • Resolution: 1%
  • Accuracy: 80%~100% ± 2 %
  • Method: Dual wavelength LED
Heart (Pluse) Rate
  • Range: 30 to 250bpm
  • Resolution: 1bpm
  • Accuracy: ±1 bpm or ±1% when HR < 100 bpm
Displays
  • Type: LCD display with backlight
  • Parameters: SpO2; Pulse rate; Pulse bar (also indicate perfusion index )
  • Status: Indicate a stable reading is taken; Battery status indication
Mechanical
  • Weight:< 39 g (Without battery)
  • Dimension: 63mm (L) x 38mm (W) x 37mm (H)
Battery
  • Typel: Alkaline battery AAA x 2
  •  Usage life: >40 hrs
Enviromental
  • Operating Condition: 10°C~40°C (50°F~104°F)
  • Storage Condition: -25°C ~ 70°C (-13°F ~ 158°F)
  • Operating humidity: 10% to 95%, non-condensing
Classification
  • Degree of protection: Type BF Applied part
  • Mode of operation: Spot Check
  • Water-resistance: IPX4
  • Safety: IEC60601-1
  • EMC: IEC60601-1-2
  • Performance standard: ISO9919

More Less

About us

Company details

We focus on providing complete solutions covering Home Care (Blood Pressure Monitor, Thermometer, Nebulizer) , Diagnostics (HbA1c, Blood Glucose, Ketone, Cholesterol, Uric Acid, Lactate, Multi-functional monitoring system), Professional Instrument (Vital Sign Monitor, ECG Recorder, Pulse Oximeter) and TeleHealth System (devices with Bluetooth connectivity) .

Moving forward in a demanding and dynamic business environment, We projects ourselves as a world-class healthcare solution provider in the future.

We aim to obtain the world-class reputation on R&D and manufacturing by successive innovation and integration. Thus, becoming the best medical device manufacturer worldwide and leading Taiwanese healthcare industry towards the top world class, are the commitment to our clients.

More Less

Company data

Sales volume

100-199 Mio US $

Export content

> 75%

Number of employees

500-999

Area of business
  • Electromedical equipment / Medical Technology
  • Diagnostics

Company information as a PDF file