Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves

Our products

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

STEAM STERILIZER – SLIDING / FLYWHEEL DOOR – SINGLE / DOUBLE DOOR

Control system based on micro-computer technology, ensuring safe operation
The computerized control unit assuring a fully automatic operation throughout the entire
cycle
All sterilization phases are displayed and controlled on LCD touch screen display
Chamber, steam jacket, door and steam generator that are made of 316 L stainless steel
Single/Double Sliding Door or Single/Double Flywheel Door
Production between 125-1200 L volume on demand
Generator power: varies according to device capacity
Working pressure: 3.5 bar, test pressure: 7.2 bar
Pressure measurement: -1.0/+5.0 bar
Temperature measurement: 100 °C-140 °C (± 1 °C)
Silicon seal ensuring impermeability against acid and chemical substances
Manuel system for emergency situations
Automatic open-close for sliding door systems
Pneumatic or automatic electro motor controlled sliding doors having required features
Door safety lock and Door closing safety
Special safety valve (CE) in chamber and jacket, PT 100 heat sensor, pneumatic valves in
the steam lines
4 pieces of calibrated manometers for single door models and 8 pieces for double door
models vessel, jacket, generator and seal
HEPA filter filtering particles larger than 0.3 micron (%99.99)
Water saving system, standby mode, fast heating mode
Preset program and user-defined custom program memory (121 °C – 134 °C)
Test programs: Bowie&Dick and vacuum leakage.
Bypass system
High capacity, quiet running vacuum pump with water ring
PLC (Microprocessor) control system with color touch screen – touch screen for clean side
in double door models
RS232 I RS485 output, optional
Independent record system from automatic control system
Visual, written and audio alarm system indicating the status of fault on the display

More Less

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

VERTICAL TYPE STEAM STERILIZER FLYWHEEL / SLIDING DOOR

Chamber volume: 75-90 L
AISI 316L stainless steel chamber and jacket material
AISI 304 quality stainless steel outer coating material
Stainless steel steam installation
High capacity, quiet running vacuum pump with water ring
Bypass system: for vacuum pump safety
Air filter: 0.3 micron% 99.99 HEPA filter
The control system based on micro-computer technology, ensuring safe operation
Water level control
All sterilization phases are displayed and controlled on LCD touch screen displays
Preset programs and user defined custom programs (121 °C – 134 °C}
Test programs: Bowie&Dick and vacuum leakage
Max. chamber pressure 3 bar, double-walled
Sterilization time: 0-99 min. (±1) min.
Drying time: 0-99 min.
Pressure measurement: -1.01+5.0 bar
Vacuum breaking system
Heat measurement: 100°C-140°C (± 1 °C)
Generator power: Varies according to device capacity
Heating system: Electronically controlled
Silicon seal for leakage
Separate pressure manometers for chamber and jacket
Test and alarm conditions
RS 232/RS485 output system (Optional)
Printing sterilization parameters with optional printer
Resistance: Varies according to device capacity
Electronic and mechanical safety controls
Electromagnetic or pneumatic steam control mechanisms

More Less

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

SINGLE / DOUBLE DOOR

The equipment automatically disinfects general surgical tools, materials for general anesthesia, urology, gynecology, operating room, orthopedics and feeding bottles together with the nipples by making use of the appropriate optional basket
Device volume varies from 100-500 L
Manuel or sliding door
The device is fully electronically controlled
Device has at least 64 programs 4 of which are standard and 60 of which are empty memory peculiar to user for special programming purposes
There is optional RS 232 serial interface for the computer / printer that is to be specified in the order for reporting
The command system indicates the general washing process and the general operating deficiencies on the LCD screen
The device gives an written and audio alarm signal at the end of the program
There must be double temperature sensors to ensure the washing and the disinfection in a healthy manner in the device in compliance with the international medical devices directive, where one of these temperature sensors are for commanding the temperature and the other is for controlling the temperature
The equipment may be used under the bench by taking its upper cover
The equipment should be double walled for noise and heat insulation
There is an integrated mono block water softener unit in the device (Optional)
There is a filter system that comprises 4 stages in washing cabinet
These are the synthetic coarse filter, surface filter that is made of stainless steel, micro filter that is made of stainless steel and the strainer tray filter that is is made of stainless steel
Steam condenser system is available to prevent the outlet of the contaminated steam from the equipment
There is 1 internal automatic dosage pump for the liquid detergent dosage and there is 1 automatic dosage pump for the acidic chemicals (for the neutralization process)
The equipment can dry the internal parts and the external parts of the washed materials by generating hot air or through the drying resistance

More Less

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

WASHER AND STEAM STERILIZER

The Washer and Steam Sterilizer which was developed after research and development, is a sterilization revolution which was produced with the latest technology
Ensures 100% safe sterilization of the surgical materials and feeding bottles. The purpose
of the washing program is to provide the physical agents to reach more easily to the surface to be sterilized, providing a hygienic medium by carrying out a preliminary washing before sterilization. Moreover, it provides saving from time and work since it has the hand washing process that the hospital personal has to carry out by hand before the sterilization process.
Control system based on micro-computer technology, ensuring safe operation and computerized control unit assuring a fully automatic operation throughout the whole cycle.
All sterilization and washing phases are displayed and controlled on PLC touch screen display
Generator power: Varies according to device capacity
Chamber, steam jacket, door and steam generator made of stainless steel
Production between 96-125 L and 250 L
Max. chamber and the jacket pressure 3.0 bar, operating pressure: max. 2.5 bar
Temperature measurement: 1ooac -140°C (± 1ac )
Pressure measurement:- 1.0/+ 5.0 bar (at a sensitivity of ± 0.1 bar)
Silicon seal ensuring impermeability against acid and chemical substances
Manuel system for emergency situations, door safety lock and door closing safety
PT 100 heat sensor, pneumatic valves in steam lines
Safety valves, (CE) valves, and calibrated manometers in chamber and jacket
HEPA filter: filtering particles larger than 0.3 micron (%99.99)
Water saving system, standby mode
Washing program
Preset and user-defined custom program memory
Test programs: Bowie&Dick and vacuum leakage
Automatic cut-off in case of water shortage
Pre-heat, pre-vacuum, adjustable drying time, bypass system
High capacity, quiet running vacuum pump with water ring
RS232 I RS485 output, optional Visual, written and audio alarm system indicating the status of fault on the display

More Less

About us

Company details

Our company titled as Sümer International Industry and Trade Inc. is an organization that serves the health sector until today as of 1981 through its manufacturing and import activities and is an organization that has its power especially in Neonatology, Sterilization and General Surgical areas.
Our company is following the innovations in the sector and abroad through its research and development unit and application staff having engineering infrastructure and adopted the aim to develop and produce these high-tech devices developed in line with these innovations as to be benefitted best by humankind and our country.
Our products are in compliance with the current technology and have been produced at equivalent quality with their western samples and they bear all the properties as required by Turkish Standards (TSE) and the European Union Standards (CE).
Our company conducts the projects supported by TÜBiTAK (The Scientific and Technological Research Council of Turkey), KOSGEB (Small and Medium Enterprises Development Organization), Ankara Development Agency and Ministry of Science, Industry
and Technology.
Ankara Chamber of Industry gave us Success Award for the year 2012 and R&D award for the year 2011 on 27/12/2012.

OUR VISION
Our vision is to be an innovative medical company that develops and follows the latest technologies and has a say in the market.

OUR MISSION
Our mission is to develop a competitive, dynamic, fast and effective production system that operates in a customer focused manner.

More Less