MSLINE ENG. Co., Ltd. of Icheon-si, Gyeonggi-do at MEDICA 2017 in Düsseldorf -- MEDICA Trade Fair
Manufacturers OEM

MSLINE ENG. Co., Ltd.

Unit 205, 3321, Kyeongchung-daero,Sindun-myeon, 17303 Icheon-si, Gyeonggi-do
Korea, Republic

Telephone +82 31 6451325
Fax +82 2 20981665
yjkwon1023@mslineeng.com

This company is co-exhibitor of
Korea Medical Devices Industrial Coop. Association (KMDICA)

Hall map

MEDICA 2017 hall map (Hall 16): stand B65

Fairground map

MEDICA 2017 fairground map: Hall 16

Contact

Kevin Kwon

Phone
+821088657055
+82322165022

Email
yjkwon1023@mslineeng.com

Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.02  Imaging proceedings
  • 01.02.05  X-ray devices and accessories

X-ray devices and accessories

  • 01  Electromedical equipment / Medical Technology
  • 01.02  Imaging proceedings
  • 01.02.05  X-ray devices and accessories
  • 01.02.05.19  Mobile X-ray apparatus

Mobile X-ray apparatus

  • 01  Electromedical equipment / Medical Technology
  • 01.02  Imaging proceedings
  • 01.02.05  X-ray devices and accessories
  • 01.02.05.35  Accessories for x-ray generators

Accessories for x-ray generators

  • 01  Electromedical equipment / Medical Technology
  • 01.02  Imaging proceedings
  • 01.02.05  X-ray devices and accessories
  • 01.02.05.36  X-ray generators for radiotherapy and diagnostic radiology

X-ray generators for radiotherapy and diagnostic radiology

  • 01  Electromedical equipment / Medical Technology
  • 01.02  Imaging proceedings
  • 01.02.05  X-ray devices and accessories
  • 01.02.05.43  X-ray protection items

X-ray protection items

  • 01  Electromedical equipment / Medical Technology
  • 01.02  Imaging proceedings
  • 01.02.05  X-ray devices and accessories
  • 01.02.05.49  X-ray table covers and other auxililary equipment

X-ray table covers and other auxililary equipment

Company news

Date

Topic

Download

Sep 1, 2017

Performance of a protector agains scattered radiation during intraoperative use of a C-arm

IOP Publishing Society for Radiological Protection

Performances of a protector against scattered radiation during intraoperative use of a C-arm fluoroscope

Ki Hyuk Sung, Young-Jun Jung, Soon-Sun Kwon,
Gye Wang Lee, Chin Youb Chung, Kyoung Min Lee,
Hyemi Cha, Moon Seok Park, and Kisung Lee
1 Department of Orthopaedic Surgery, Seoul National University Bundang Hospital,
300 Gumi-Dong, Bundang-Gu, Seongnam, Gyeonggi 13620, Korea
2 Department of Bio-convergence Engineering, Korea University,
145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
3 Department of Mathematics, College of Natural Sciences, Ajou University,
206 Worldcup-ro, Yeongtong-gu, Suwon, Gyeonggi 16499, Korea
4 Department of Orthopaedic Surgery, DK Dongcheon Hospital, 215 Oesolkeun-gil,
Jung-gu, Ulsan 44495, Korea
5 School of Biomedical Engineering, Korea University, 145 Anam-ro, Seongbuk-gu,
Seoul 02841, Korea
E-mail: kisung@korea.ac.kr and pmsmed@gmail.com
Received 10 March 2016, revised 20 July 2016
Accepted for publication 22 July 2016
Published 12 August 2016

Abstract
The scattered radiation protector for mobile x-ray systems, Creative Valuable
Protector-2, has been recently developed. However, there have been no studies
investigating the effects of this device. We aim to investigate the effects of the
scattered radiation protector on the equivalent doses from scattered radiation
delivered to radiosensitive organs while simulating spine surgery using a
C-arm fluoroscope. Chest and rando phantoms were used to simulate a patient
and a surgeon in this study. The equivalent dose from scattered radiation to
radiosensitive organs was measured in four different situations according to
the use of the scattered radiation protector and the C-arm configuration. To
compare the quality of the images with and without the scattered radiation
protector, an acryl step phantom with five steps was used, and the contrast
resolution of each step was calculated. The equivalent dose from the scattered
radiation to the surgeon’s eye, thyroid, and gonad decreased significantly

More Less

About us

Company details

MSLINEENG. Co., Ltd. was established in 29th of April, 2011,
to improve the environment of clinics and hospitals. After a 5 year research with Korea Institute of Ceramic Engineering and Technology, the world’s first radiation filtering device, CVP-2, was developed. Also, after obtaining approval from organization such as FDA, KFDA, ISO, CE, KTL, etc.
we have begun distributing our products not only domestically but also worldwide. Our company will do its best to reduce the radiation exposure for medical staff throughout the world. Currently it has been installed in more than 300 hospitals in Korea alone.

History
2011.04 MSLINEENG Co., Ltd. was established
2011.07 2 patents registered for CVP-2
2012.11 CE certificate
2013.05 FDA approved
2016.2. Antiscattering filter CVP-2 upgraded version

More Less