REAGENS Kft of Budapest at MEDICA 2017 in Düsseldorf -- MEDICA Trade Fair
Manufacturers

REAGENS Kft

Wysocki utca 1, 1155 Budapest
Hungary

Telephone +36 1 3498775
office@reagenskft.hu

Hall map

MEDICA 2017 hall map (Hall 18): stand D01

Fairground map

MEDICA 2017 fairground map: Hall 18

Our range of products

Product categories

  • 03  Diagnostics
  • 03.03  Haematology / Histology / Cytology
  • 03.03.09  Immunohaematology (Blood grouping)

Immunohaematology (Blood grouping)

  • 03  Diagnostics
  • 03.03  Haematology / Histology / Cytology
  • 03.03.09  Immunohaematology (Blood grouping)
  • 03.03.09.01  Diagnostic agents / kits for immunohaematology

Diagnostic agents / kits for immunohaematology

  • 03  Diagnostics
  • 03.03  Haematology / Histology / Cytology
  • 03.03.09  Immunohaematology (Blood grouping)
  • 03.03.09.04  Control material for immunohaematology

Control material for immunohaematology

  • 03  Diagnostics
  • 03.03  Haematology / Histology / Cytology
  • 03.03.09  Immunohaematology (Blood grouping)
  • 03.03.09.05  Reagents for immunohaematology

Reagents for immunohaematology

  • 03  Diagnostics
  • 03.03  Haematology / Histology / Cytology
  • 03.03.09  Immunohaematology (Blood grouping)
  • 03.03.09.06  Accessories for immunohaematology

Accessories for immunohaematology

Our products

Product category: Immunohaematology (Blood grouping)

ReaCell AB0 Test Cells

The ReaCell AB0 Test Cells are in vitro diagnostic medical devices (IVDMD) of human origin. They are designed for analysis of human biological samples. These test cells are being used for determination of AB0 blood group antibodies (anti-A, anti-B) in human serum or plasma.

The detection of anti-A and/or anti-B in the serum/plasma is a complementary part of blood grouping; by the presence or absence of anti-A and/or anti-B antibodies supports the evaluation of the reactions between the red blood cells and test sera.

On natural conditions the serum/plasma of persons with “A” blood group contains anti-B antibodies, the serum/plasma of persons with “B” blood group contains anti-A antibodies, the serum/plasma of persons with “0” blood group contains either anti-A or anti-B, and the others with “AB” blood group contains neither anti-A, nor anti-B.

If the serum/plasma to be tested contains anti-A, it will agglutinate the A1 and A2 test cells.

The ReaCell AB0 Test Cells containing variation of vials of blood grouping cells
A1,A2, B, 0, with different reference numbers, see Packaging. The A1 group test cells are RhD negative.

The red blood cells are prepared in the method wanted concentration ready-to-use, preservative suspension, filled in 5 ml and 10 ml vials fitted with a calibrated dropper.

More Less

Product category: Diagnostic agents / kits for immunohaematology

ReaCell Panel Cells

The ReaCell Panel Cells are in vitro diagnostic medical devices (IVDMD) of human origin to detect patient's and donor's irregular (IgM and IgG) antibodies, which may cause haemolitic anemia, transfusion reactions and complications, and haemolitic disease of the newborn. These antibodies were detected with previous screening and/or cross matching probes.

The non-enzymatised ReaCell Panel Cells detect IgM (mainly M, N) and IgG (Rh-, Kell-, Duffy-, Kidd-, etc.) system's irregular antibodies with direct agglutination, and indirect antiglobulin (indirect Coombs) technique.

The ReaCell Panel P enzymatised (papainised) Panel Cells are reacting in enzymatised medium IgM and IgG, for detecting mainly Rh system's irregular antibodies with direct agglutination technique. The Kell system's antibodies may react this way as well. The  Panel Cells are able to detect several cold IgM antibodies (anti-I, Anti-H, anti-P1, anti-Lea, anti-Leb). The enzym treatment destroys the Fya, Fyb, M, N and partially S antigens, this kind of antigens can't be detected with enzymatised Panel Cells.

Each ReaCell Panel Cells Kit contains 11 pieces of „0” group, known antigen composition red blood cells suspension.

More Less

Product category: Control material for immunohaematology

Internal Quality Control

The Rea IQC Total Blood Kit is in vitro diagnostic medical devices (IVDMD) of human origin for completing the AB0-Rh1 blood grouping series (red blood cells test and plasma tests) and Rh-K phenotyping series. The use of this internal control enables detection of different irregular and malfunctions caused by the used method, by the used reagent, by the used instrument and environment. Make possible to take preventive and corrective actions.

The internal control test is based on  blood samples with well known, determined phenotypes. This control is used in the same way as the normal patient blood samples. The results of this samples testing should match exactly the blood groups phenotype on the vial. The test is based on the principle of haemagglutination. The RBC with antigen agglutinates the antibody of the used reagent or plasma.

Rea IQC Total Blood Kit contains RBC and plasma with determined, well known blood group and phenotype. The suspension HTC level is between 25% to 30%.

More Less

Product category: Reagents for immunohaematology

ReaCell Screening Cells

The ReaCell Screening Cells are in vitro diagnostic medical devices (IVDMD) of human origin to detect patient's and donor's irregular (IgM and IgG) antibodies, which may cause haemolitic anemia, transfusion reactions and complications, haemolitic disease of the newborn.

The non-enzymatised ReaCell I, II, III Screening Cells detect IgM (mainly M, N) and IgG (Rh-, Kell-, Duffy-, Kidd-, etc.) system's irregular antibodies with direct agglutination, and indirect antiglobulin (indirect Coombs) technique.

The ReaCell IP, IIP, IIIP enzymatised (papainised) Screening Cells are reacting in enzymatised medium IgM and IgG, for detecting mainly Rh system's irregular antibodies with direct agglutination technique. The Kell system's antibodies may react this way as well. The  Screening Cells are able to detect several cold IgM antibodies (anti-I, Anti-H, anti-P1, anti-Lea, anti-Leb). The enzym treatment destroys the Fya, Fyb, M, N and partially S antigens, this kind of antigens can't be detected with enzymatised Screening Cells.

The ReaCell Screening Cells contains 3-3 „0” group, with known antibody property suspension. We are providing for each batch an antigen chart with the product. It is also available for registered users to dowload in pdf format.

More Less

Product category: Immunohaematology (Blood grouping)

Other serology products

Immunohematology

More Less

About us

Company details

REAGENS Ltd. was established by three owners in 1990, with over 25 years experience in manufacturing and distributing of medical devices and reagents.

REAGENS played a pioneer role in introducing environment friendly new reagents to the Hungarian market.

As a result of continuous and intensive technology development only REAGENS preserves red blood cells in Hungary for blood serology purposes.

By manufacturing and distributing of ReaCell branded AB0, Screening and Panel cells, together with the internal and external immunohematology control products, REAGENS Ltd. achieved a significant market share. 

In order to fulfill our customers request at a high quality level – we are distributing many more products of foreign companies.

More Less