SPARKER INTERNATIONAL CORP of Alhambra, CA at MEDICA 2017 in Düsseldorf -- MEDICA Trade Fair
Manufacturers Trader

SPARKER INTERNATIONAL CORP

245 E Main Street #115, 91801 Alhambra, CA
USA

Telephone +1 323 9088554
info@sparkerintl.com

Hall map

MEDICA 2017 hall map (Hall 11): stand D58

Fairground map

MEDICA 2017 fairground map: Hall 11

Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.04  Intense medicine / anesthesiology / respiration
  • 01.04.04  Patient monitoring systems / Measuring stations

Our products

Product category: Patient monitoring systems / Measuring stations

Mini ECG - TCL-200

In Europe the main cause of mortality is cardiovascular disease or CVD (e.g. stroke, heart attack, heart failure).  And according to WHO, CVD is the first killer all over the world. 
Under this status, we developed a new home monitoring device. The new Handheld ECG Monitor senses the heart waveform and indicates potential ECG abnormalities.

Specifications

● Portable and easy to operate; Independent on cable and electrode. 
● LCD Screen display ECG waveform, Heart Rate, Analyses, and Power.
● Dual measuring modes:30-second quick measurement, continuous mode.
● 200 ECG records-30 second ECG waveform and analysis. 
● 13 kinds of analysis modes for the esamination of arrhythmia.
● Review records freely; Transmit records to PC via USB.
● 2 batteries, At least 500 times' measurements.

More Less

Product category: Patient monitoring systems / Measuring stations

Patient ECG - iPM 42-1

Description

Patient monitor is a kind of instrument or system which is used to easure  and control patients' physiological parameters, which can be compared with  known settings, if they are higher than know settings, the system will alarm.

Features

● Ergonomic design, portable, convenient for use.  
● 15" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters. 
● Unique digital SPO2 technology can work accurate during motion and low perfusion.  
● Anti AC & high-frequency electrosurgical & defibrillator’s interference. 
● Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others.  
● Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events.  
● ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation.  
● Audible & visual alarm available, adjustable.  
● Patient information management function. 
● Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room. 
● Optional software upgrading based on USB. 
● Wired/wireless networking with central monitoring system, up to 64 beds in one group.  
● Built-in 3 trace thermal recorder for printing real-time and historical data.  
● Multi-language i.e. English, Spanish, Turkish.  
● Super long life rechargeable Lithium battery upto 4 hours of working time. 
● Suitable for adult, pediatrics and neonate patients.

More Less

Product category: Patient monitoring systems / Measuring stations

Neonatal ECG - NE1-500

The features of software

* Quick and accurate analysis system. 
* With 12 leads synchro analysis , QRS search can be more exactly.
* There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. 
* Optional main channel. 
* Agile and exact "Atrial Fibrillation" analysis. 
* The function of pacing analysis could analyse all pacemakers. 
* Many pacine modules have been added. 
* Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis. 
* The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG. 
* Print report expediently.

Recorder Features

● With advanced design and technology, the recorder can work stably, dependable and durable.  
● Be provided with the capability of anti-jamming and shock-pro. 
● Small volume with OLED screen. The resolution is 160*128. 
● Be provided with functions of waveform preview, record review and event marking. 
● Accurate record of the start time of the data sampled owing to the real time clock of itself. 
● Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. 
● The maximum capability can be 2GB, so the original data can be saved erfectly by no compression. 
● The average review time of single case can be less than 40 seconds by using interface of USB 2.0. 
● Record waveform details inextenso by the design of high precision and sampling frequency. 
● Record the state of pacemaker exactly by higher sampling frequency. 
● International standard of 12 leads. Record 24-hour DECG with the same standard of the ECG. 
● Perfect function of case management.  
● With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally. 
● "Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose. 
● "HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately. 
● "T Wave alternation" analysis is a important index on judging and preventing Arrhythmia. 
● The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.

Standard

▶ Number of channels: 12 channels; 
▶ Sampling rate:10000Hz; 
▶ Sampling accuracy:12bit; 
▶ Recording time : 24 h; 
▶ Power: 2 batteries in size 5; 
▶ Interface: USB2.0; 
▶ Scale voltage:1mV±5%; 
▶ Standard Sensitivity:10mm/mV±5%; 
▶ Noise level:≤30μV; 
▶ CMRR:≥60dB; 
▶ Feathers of low frequency : Time constant>3.2s; 
▶ Scan speed:25mm/s±5%; 
▶ Enduring polarization voltage:±300mV; 
▶ Least measure signal : 50 µV p-p; 
▶ Product safety type : Type B (Internally powered); 
▶ Size:111mm(L)*60mm(W)*25mm(H); 
▶ Net Weight: 102g (Without battery).

More Less

Product category: Patient monitoring systems / Measuring stations

Neonatal ECG - NE2-450

The features of software
* Quick and accurate analysis system. 
* With 12 leads synchro analysis , QRS search can be more exactly.
* There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. 
* Optional main channel. 
* Agile and exact "Atrial Fibrillation" analysis. 
* The function of pacing analysis could analyse all pacemakers. 
* Many pacine modules have been added. 
* Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis. 
* The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG. 
* Print report expediently.

Recorder Features
● With advanced design and technology, the recorder can work stably, dependable and durable.  
● Be provided with the capability of anti-jamming and shock-pro. 
● Small volume with OLED screen. The resolution is 160*128. 
● Be provided with functions of waveform preview, record review and event marking. 
● Accurate record of the start time of the data sampled owing to the real time clock of itself. 
● Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. 
● The maximum capability can be 2GB, so the original data can be saved erfectly by no compression. 
● The average review time of single case can be less than 40 seconds by using interface of USB 2.0. 
● Record waveform details inextenso by the design of high precision and sampling frequency. 
● Record the state of pacemaker exactly by higher sampling frequency. 
● International standard of 12 leads. Record 24-hour DECG with the same standard of the ECG. 
● Perfect function of case management.  
● With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally. 
● "Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose. 
● "HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately. 
● "T Wave alternation" analysis is a important index on judging and preventing Arrhythmia. 
● The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.

Standard
▶ Number of channels: 12 channels; 
▶ Sampling rate:10000Hz; 
▶ Sampling accuracy:12bit; 
▶ Recording time : 24 h; 
▶ Power: 2 batteries in size 5; 
▶ Interface: USB2.0; 
▶ Scale voltage:1mV±5%; 
▶ Standard Sensitivity:10mm/mV±5%; 
▶ Noise level:≤30μV; 
▶ CMRR:≥60dB; 
▶ Feathers of low frequency : Time constant>3.2s; 
▶ Scan speed:25mm/s±5%; 
▶ Enduring polarization voltage:±300mV; 
▶ Least measure signal : 50 µV p-p; 
▶ Product safety type : Type B (Internally powered); 
▶ Size:111mm(L)*60mm(W)*25mm(H); 
▶ Net Weight: 102g (Without battery).

More Less

Product category: Patient monitoring systems / Measuring stations

Pet ECG - PT1-350

Pet ECG measurement
*  Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed.
*  Gains options:   × 1, × 2, × 0.25, and × 0.5 four trenches.
*  Frequency: 0.5 Hz - 100 Hz.
*  Common-mode signal inhibition: More than 70 dB.
*  Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
*  HR: ± 5 bpm
*  Precision calibration signal: 1mv(peak, ± 3% accuracy).
*  ST Detection: measurement range (-2.0mV----+2.0mV).
*  Using Standard: meet the ANSI / AMI EC13 -2002 standard.
*  Response time: 1s.
*  Alarm: Sound and Light
*  Preset heart rate range: (Alarm over preset numerical).
*  Ceiling:1-255 bpm adjustable.
*  Threshold:0-254 bpm adjustable.
*  Technology:Oscillography.
*  Measuring method: negative measurement data is more accurate.
*  Mode: manual / automatic.
*  Measurement units: mmHg / kpa.
*  Protection: Double security protection.
*  A measurement time: less than 45 S.
*  Scope: Pressure Cuffs 0-250 mmHg.
*  Blood pressure measurement accuracy: ANSI /AAMI, SP10-2002 standard error and standard deviation of the average value of the initial.
*  Inflatable cuffs: 180 mmHg (120 mmHg children   newborn 70 mmHg).
*  Inflatable cuffs follow: original SBP: + 30 mmHg.
*  Blood pressure measuring range: Systolic blood pressure: 60-250 mmHg Diastolic blood pressure: 40-220 mmHg Pressure on the average: 45-235 mmHg Response time: 1s.
*  Alarm: Sound and Light.
*  Preset range: report (Numerical exceed preset alarm) .
*  Systolic blood pressure maximum: 1-255 mmHg adjustable.
*  Threshold: 0-254 mmHg adjustable. 
*  Diastolic blood pressure ceiling: 1 -255 mmHg adjustable.
*  Minimum standards: 0-254 mmHg adjustable.
*  Use standard: compliance with the ANSI / AAMI SP10-2002 standard.

Features
● The new high-precision modules, high precision measurement parameters, reliable quality and stable performance.
● High brightness resolution 12.1 inches color TFT LCD display, waveform data is clearly visible. 
● Jog shuttle operation, in English logo button, easy to use, simple and intuitive operation.
● All leads seven-channel synchronous ECG display.
● ST segment automatic detection, arrhythmia analysis, drug concentrations drop table analysis.
● NIBP dual overvoltage drift control and many other technology to ensure accurate measurement, to protect patient safety.
● Powerful storage capability, the entire fully parametric trend chart data, ECG waveform storage playback, power-down save function.
● Automatic sound and light dual alarm, the alarm can be set upper and lower limits.
● Body is Light weight and sturdy, easy to carry, suitable for cat, dog and other mammals.
● Anti defibrillation, anti electrosurgical interference.
● Support for wired and wireless networking capabilities, support online software upgrades.
● Optional built-in rechargeable lithium battery, AC-DC dual-use. 
● Optional built-in two-channel thermometer recorder, real-time waveforms and print icon print.
● Widely used in all kinds of pet clinic, pet hospital, veterinary station and zoo.

Standard Configuration
▶ Pet monitor×1 set
▶ Pet ECG clip joint connecting cables×1 set 
▶ Pet blood pressure cuffs×1 set 
▶ Pet SPO2 probe×1 set
▶ TEMP probe×1 set
▶ Power plug line×1 PCS
▶ Grounding wires×1 PCS

Optional
Build-in rechargeable lithium battery; build-in thermal printer; monitor mobile stand/ cart.

Spo2 Measurement
▷ Range: 0-100% Accuracy: 1% 
▷ Resolution: 1% 
▷ Pulse frequency: 20-250 times/min
▷ Response time: 1s
▷ Alarm: Sound and Light
▷ Preset range: Report Alarm over preset numerical
▷ Ceiling:1% - 100% adjustable
▷ Threshold:0% - 99% adjustable

TEMP Measurement
▷ Technology: thermostat temperature probe
▷ Measuring range: 20°C-45°C 
▷ Temperature resolution: 0.1% 
▷ Accuracy: ± 0.1°C 
▷ Response Time: 1s 
▷ Alarm: Sound and Light 
▷ Preset range: Report (numerical preset alarm over)
▷ Maximum: 20.1°C-45.5°C adjustable 
▷ Threshold: 20°C-45.4°C Adjustable

RESP Breath
▷ Breathing frequency range: 0-60 bum
▷ Accuracy: ± 1rpm
▷ Response time:  1s
▷ Gains options: × 1, × 2, × 4, and × 0.5 four trenches
▷ Alarm: Sound and Light
▷ Alarm range:Numerical preset alarm over
▷ Ceiling:10-100 bpm adjustable
▷ Threshold:0-99 bpm adjustable

Printer(Optional)
▷ Specification: Dual channel thermal array data recorder 
▷ Print mode: Real time or event triggered record waveform and text 
▷ Accuracy: horizontal: 400dpi   vertical: 800dpi 
▷ Annotation: time(24)

System
▷ Display selection:12.1 inch color TFT true color LCD screen 
▷ Battery (optional): Lead-Acid battery sealed maintenance-free 
▷ Security labels: lec601-1 (International GB9706.1)

More Less

About us

Company details

What we do
The Company focuses on ECG and production of medical instruments.

How we do
We're not just making medical products, we're marketing medical care. We care how our product is, how our client feels and how the patient feels using our product!

Our concept
Care the life, we make excellent products!

Our target
Sticking to the cultural philosophy of customer-orientation and quality first, the Company is advancing with the times and continuously developing new products.

More Less